Product Number 

SRM330 

 

 

Resistance Meter with travel 

 

 

 

 

 

probes, testing plate and  

 

 

 

 

carrying case 

 

 

Specifications: 

Dimensions/Weight  

 

5.8” H x 3.50” W x 1 D /

 

 

 

7.05 oz  

Test range:  

 

 

10

3

-10

12

 

Test voltage: 

 

 

10V/100V 

Accuracy 

 

+ 5% 

Power Supply   

 

9V-Battery (PP3) 

Probes:  

 

 

Two travel probes 

 

 

 

 

 

Two 3”parallel probes

 

Read Out 

 

 

LCD  

 

Test Range 

Resistivity: 

 

 

10

3

-10

12 

ohms/sq. 

Resistance:  

 

 

10

3

-10

12 

ohms 

Accuracy 

 

 

+ 1/2 decade 

 

 

Service and Warranty 

 

 

Transforming Technologies, LLC provides a limited warranty for the 

Model SRM330. All new products are guaranteed to be free from defects 

in material and workmanship for a period of one (1) year from the date of 

shipment. Liability is limited to servicing (after evaluating, repairing or re-
placing) any product returned to Transforming Technologies. The com-

pany does not warrant damage due to misuse, neglect, alteration or acci-

dent. In no event shall Transforming Technologies be liable for collateral 

or consequential damages. To receive service under warranty, please 
contact Transforming Technologies Technical Support.

 

Product Specifications 

3719 King Rd | Toledo, OH 43617 | P: 419-841-9552 | F: 419-841-3241 | [email protected] 

Summary of Contents for Ohm Metrics SRM330

Page 1: ...Instruction Manual Continuous Workstation Monitors Model SRM330 Ohm Metrics...

Page 2: ...Ohm MetricsTM 2 2 Operation Power Option 2 Set Up 2 Parallel Probe Resistivity Testing 3 Probe Resistivity Testing 4 Resistance Between Two Points RTT 4 Surface to Ground Resistance RTG 5 3 Specificat...

Page 3: ...s of pres sure necessary for some measurements Suitable for factory audits and test lab evaluations Features include 10v and 100v range voltage selection Two Press Test lightweight travel probes Built...

Page 4: ...splayed in Ohms and is read as 10 X 1 2 decade where X is the range illuminated on the checker D Test Button Pres and hold un til the readout displays a meas urement E Battery compartment Remove cover...

Page 5: ...est 1 Place the meter on the surface to be tested 2 Move the toggle switch to Internal 3 Press and hold the test button until measurement is displayed 4 If measurement is outside acceptable limits cle...

Page 6: ...ntended test surface and press down on the spring loaded probes Have a 2nd person press the test button and hold both the probes and the button until a the measurements are displayed The SRM330 can be...

Page 7: ...a ground point on the material surface and specific positions on the material being tested This procedure complies with the EOS ESD S4 1 standard 1 Meter set up with both test leads connected to the...

Page 8: ...Model SRM330 All new products are guaranteed to be free from defects in material and workmanship for a period of one 1 year from the date of shipment Liability is limited to servicing after evaluatin...

Reviews: