INSTALLER'S GUIDE

Minimum Heating Airflow Settings

Section 7. Tables

MODEL NO.

BAYEVAC05BK1AA

BAYEVAC05LG1AA

BAYEVAC08BK1AA

BAYEVAC08LG1AA

BAYEVAC10BK1AA

BAYEVAC10LG1AA

BAYEVAC10LG3AA

BAYEVCB15LG3AA

BAYEVBC15BK1AA

BAYEVBC20BK1AA

BAYEVCC25BK1AA

TAM7A0A24H21SB

638/713

638/900

675 

1

 /900

600/713

--

--

--

--

TAM7A0B30H21SB

723/808

723/1020

765/1020

680/808

765/1063

850/1105

--

--

TAM7A0C36H31SB

876/979

876/1236

927/1236

824/979

927/1288

1030/1339

1236/1442

--

TAM7A0C42H31SB

978/1093

978/1380

1035/1380

920/1093

1035/1438

1150/1495

1380/1610

--

TAM7A0C48H41SB

1063/1188

1063/1500

1125/1500

1000/1188

1125/1563

1250/1625

1500/1750

1625/1813

TAM7B0C60H51SA

TAM7A0C60H51SB

1063/1188

1063/1500

1125/1500

1000/1188

1125/1563

1250/1625

1500/1750

1625 

1

 /1813

WITHOUT HEAT PUMP / WITH HP

SEE AIR HANDLER NAMEPLATE FOR APPROVED COMBINATIONS

1

 Heater not qualified for 208V when installed in horizontal left position without Heat Pump

MINIMUM HEATER AIRFLOW CFM - HEATER MATRIX

MODEL NO.

BAYEVAC05BK1AA

BAYEVAC05LG1AA

BAYEVAC08BK1AA

BAYEVAC08LG1AA

BAYEVAC10BK1AA

BAYEVAC10LG1AA

BAYEVAC10LG3AA

BAYEVCB15LG3AA

BAYEVBC15BK1AA

BAYEVBC20BK1AA

BAYEVCC25BK1AA

TAM8A0A24V21CB

638/713

638/900

675 

1

 /900

600/713

--

--

--

--

TAM8A0B30V21CB

723/808

723/1020

765/1020

680/808

765/1063

850/1105

--

--

TAM8A0C36V31CB

876/979

876/1236

927/1236

824/979

927/1288

1030/1339

1236/1442

--

TAM8A0C42V31CB

978/1093

978/1380

1035/1380

920/1093

1035/1438

1150/1495

1380/1610

--

TAM8A0C48V41CB

1063/1188

1063/1500

1125/1500

1000/1188

1125/1563

1250/1625

1500/1750

1625/1813

TAM8A0C60V51CB

TAM8B0C60V51CA

1063/1188

1063/1500

1125/1500

1000/1188

1125/1563

1250/1625

1500/1750

1625 

1

 /1813

WITHOUT HEAT PUMP / WITH HP

SEE AIR HANDLER NAMEPLATE FOR APPROVED COMBINATIONS

1

 Heater not qualified for 208V when installed in horizontal left position without Heat Pump

MINIMUM HEATER AIRFLOW CFM - HEATER MATRIX

MODEL NO.

BAYEVAC05BK1AA

BAYEVAC05LG1AA

BAYEVAC08BK1AA

BAYEVAC08LG1AA

BAYEVAC10BK1AA

BAYEVAC10LG1AA

BAYEVAC10LG3AA

BAYEVCB15LG3AA

BAYEVBC15BK1AA

BAYEVBC20BK1AA

BAYEVCC25BK1AA

TAMGA0A24H21SA

638/713

638/900

675 

1

 /900

600/713

--

--

--

--

TAMGA0C36H31SA

876/979

876/1236

927/1236

824/979

927/1288

1030/1339

1236/1442

--

TAMGA0C48H41SA

1063/1188

1063/1500

1125/1500

1000/1188

1125/1563

1250/1625

1500/1750

1625/1813

TAMGA0C60H51SA

1063/1188

1063/1500

1125/1500

1000/1188

1125/1563

1250/1625

1500/1750

1625 

1

 /1813

MINIMUM HEATER AIRFLOW CFM - HEATER MATRIX

SEE AIR HANDLER NAMEPLATE FOR APPROVED COMBINATIONS

1

 Heater not qualified for 208V when installed in horizontal left position without Heat Pump

Summary of Contents for BAYEVAC05BK1A

Page 1: ...ounds of electrical and mechanical experience Any attempt to repair a central air conditioning product may result in personal injury and or property damage The manufacturer or seller cannot be respons...

Page 2: ...sure the power supply matches the listing shown on the heater nameplate Section 2 General Information Section 3 Heater Assembly Labeled 8 10 kW breaker model illustrated Width Adjustment Brackets Hea...

Page 3: ...lti poise 4 way M Product Tier Multi speed 7 Major Design Modifications Letter Sequence A No Descriptor Air Handler Coil 0 Size Footprint 17 5 x 21 5 A 21 0 x 21 5 B 23 5 x 21 5 C Cooling Size Air Han...

Page 4: ...inimum Cabinet Width A B C A Maximum Cabinet Width A B C C Electric Heat Input Electric Heat kW 05 08 10 15 20 25 0 9 0 9 Connection Breaker B K Lugs L G Power Supply 208 230 1 60 1 200 1 50 A 208 230...

Page 5: ...he cabinet size they match with for example the Filler Plate for cabinet B is marked B CAB 3 Tighten the Filler Plate screws loosened previously and add a screw provided to the bottom of each plate to...

Page 6: ...rotated in order to comply with National Electric Code NEC Section 240 81 The NEC requires that circuit breakers operated verti cally must be oriented so that the on position of the breaker is upward...

Page 7: ...LGA B or C Supply Duct Flange Kit install the kit before inserting the heater STEP 3 Insert heater assembly into heater compart ment 1 Move factory wiring out of the way and into the grooves provided...

Page 8: ...to secure the factory supplied conduit nut from the inside of heater compartment 2 Connect field supplied 3 4 or 1 1 2 conduit to conduit nut Note Reducing bushings may be required for your applicati...

Page 9: ...is 45 in lbs Field wiring Factory wiring Ground Field wiring Factory wiring Ground Breaker Model LG lug Model Factory wiring Field wiring BLK BLK RED RED GREEN GREEN STEP 9 Install the seal plate Bre...

Page 10: ...PPLY PER LOCAL CODE EL EC TR IC HE AT CO NT RO L LO W VO LT AG E WI RING T11 T12 T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 EHC IN AIR HA ND LE R GR GR BK RD 3 1 HIG H VOL TAG E WIR ING IN AIR HAN DLE R MOD EL BA...

Page 11: ...LT S 208 VOLT S 4 80 20 4 80 20 3 6 1 7 3 3 6 17 3 C 4 80 20 3 6 1 7 3 CIRC UIT I CIRC UIT II 9 60 40 9 60 40 7 20 34 6 7 20 3 4 6 D 4 80 20 3 6 1 7 3 TOTA L HEAT ER RATI NGS KW A MPS RD RD RD RD RD R...

Page 12: ...900 675 1 900 600 713 TAM8A0B30V21CB 723 808 723 1020 765 1020 680 808 765 1063 850 1105 TAM8A0C36V31CB 876 979 876 1236 927 1236 824 979 927 1288 1030 1339 1236 1442 TAM8A0C42V31CB 978 1093 978 1380...

Page 13: ...f the jumper is moved to another kW rating and power is applied the factory programming on the PARK position is lost The jumper must then be applied to the appropriate rating per the heater model numb...

Page 14: ...or by the kW jumper position 3 The AFC sends a command to the serial communicating blower motor to run proper airflow and close the blower interlock relay on the EHC 4 As demand from the thermostat i...

Page 15: ...Page 15 INSTALLER S GUIDE...

Page 16: ...Since the manufacturer has a policy of continuous product and product data improvement it reserves the right to change design and specification without notice Trane 6200 Troup Highway Tyler TX 75707...

Reviews: