
10
18-AC78D1-6
STEP 5 - Replace the pressure tap valve cores and
caps after the service valves have cooled.
LIFT
STEP 2 - Check for leaks by using a soapy solution
or bubbles at each brazed location.
LIFT
Section 8. Refrigerant Line Leak Check
8.1 Check For Leaks
STEP 1 - Pressurize the refrigerant lines and evapo-
rator coil to 150 PSIG using dry nitrogen.
150 PSIG