12
CVHE-SVX005B-EN
Type of Requirement
Trane Supplied
Trane Installed
Trane Supplied
Field Installed
Field Supplied
Field Installed
Relief
•
Rupture disk assembly
•
RuptureGuard
™
(optional); refer to
Installation, Operation,
and Maintenance:
RuptureGuard Pressure
Relief System Option
(CTV-SVX06*-EN)
•
Vent line and flexible connector and vent line from
rupture disk to atmosphere
Insulation
•
Insulation (optional)
•
Insulation
•
Chiller feet insulation
Water Piping Connection
Components
Flanged (optional)
•
Welded on flange for
300 psig (2068.4 kPaG)
waterboxes
Flanged (optional)
•
Victaulic
®
to flange
adapter for 150 psig
(1034.2 kPaG)
waterboxes
Victaulic
®
•
Victaulic
®
coupling for 150 psig (1034.2 kPaG) and
300 psig (2068.4 kPaG) waterboxes
•
Fasteners for flanged-type connections (optional)
Other Materials
•
Trace gas (1 lb [0.45 kg] maximum per machine as
needed to perform leak testing)
•
Material and equipment to perform leak testing
•
Dry nitrogen (8 psig [55.2 kPaG] maximum per
machine as needed)
“Appendix B: Chiller
Installation Completion
and Request for Trane
Service,” p. 99
(CTV-
ADF001*-EN; refer to
“,”
)
•
To be completed by installing contractor prior to
contacting Trane for start-up
Chiller start-up
commissioning
(a)
•
Trane, or an agent of
Trane specifically
authorized to perform
start-up of Trane
®
products
Post-commissioning
transport of empty
refrigerant containers for
return or recycling
•
Move empty refrigerant containers to an easily
accessible point of loading
(a)
Start-up must be performed by Trane or an agent of Trane specifically authorized to perform start-up and warranty of Trane
®
products. Contractor shall
provide Trane (or an agent of Trane specifically authorized to perform start-up) with notice of the scheduled start-up at least two weeks prior to the
scheduled start-up.
Storage Requirements
N
No
otte
e:: If the chiller is stored outdoors for any amount of
time, d
do
o N
NO
OT
T rre
em
mo
ov
ve
e A
AN
NY
Y ssh
hiip
pp
piin
ng
g
cco
ov
ve
erriin
ng
gss.. P
Prro
otte
ecctt tth
he
e cch
hiilllle
err ffrro
om
m tth
he
e
e
elle
em
me
en
nttss a
an
nd
d p
prro
otte
ecctt a
ag
ga
aiin
nsstt ffrre
ee
ezziin
ng
g,,
especially if any shipping materials have been
removed.
N
NO
OT
TIIC
CE
E
E
Eq
qu
uiip
pm
me
en
ntt D
Da
am
ma
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o p
prro
otte
ecctt tth
he
e u
un
niitt ffrro
om
m ffrre
ee
ezziin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n e
eq
qu
uiip
pm
me
en
ntt d
da
am
ma
ag
ge
e..
IIff ffllu
uiid
d h
ha
ass b
be
ee
en
n a
ad
dd
de
ed
d tto
o tth
he
e p
piip
piin
ng
g,, tth
he
e u
un
niitt m
mu
usstt
b
be
e p
prro
otte
ecctte
ed
d ffrro
om
m ffrre
ee
ezziin
ng
g.. F
Frre
ee
ezze
e d
da
am
ma
ag
ge
e ffrro
om
m
a
an
n u
un
nh
he
ea
atte
ed
d e
eq
qu
uiip
pm
me
en
ntt rro
oo
om
m iiss n
no
ott tth
he
e T
Trra
an
ne
e
cco
om
mp
pa
an
ny
y''ss rre
essp
po
on
nssiib
biilliitty
y.. T
Th
he
esse
e a
arre
e iin
nd
do
oo
orr u
un
niittss..
N
NO
OT
TIIC
CE
E
IIn
nssu
ulla
attiio
on
n D
Da
am
ma
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w tth
he
esse
e iin
nssttrru
uccttiio
on
nss cco
ou
ulld
d rre
essu
ulltt iin
n
iin
nssu
ulla
attiio
on
n d
da
am
ma
ag
ge
e..
T
To
o p
prre
ev
ve
en
ntt d
da
am
ma
ag
ge
e tto
o ffa
acctto
orry
y iin
nsstta
alllle
ed
d iin
nssu
ulla
attiio
on
n::
••
D
Do
o n
no
ott a
allllo
ow
w tth
he
e iin
nssu
ulla
attiio
on
n tto
o b
be
e e
ex
xp
po
osse
ed
d tto
o
e
ex
xcce
essssiiv
ve
e ssu
un
nlliig
gh
htt.. S
Stto
orre
e iin
nd
do
oo
orrss o
orr cco
ov
ve
err w
wiitth
h
cca
an
nv
va
ass tto
o p
prre
ev
ve
en
ntt e
ex
xp
po
ossu
urre
e..
••
D
Do
o n
no
ott u
usse
e tth
hiin
nn
ne
errss a
an
nd
d sso
ollv
ve
en
nttss o
orr o
otth
he
err tty
yp
pe
ess
o
off p
pa
aiin
ntt.. U
Usse
e o
on
nlly
y w
wa
atte
err b
ba
asse
e lla
atte
ex
x..
Less than 1 month
1–6 months
Greater than 6 months
Location requirements:
•
Solid foundation
•
Vibration free
•
Dry
•
Temperature range -40°F to 158°F
(-40°C to 70°C)
Location requirements:
•
Solid foundation
•
Vibration free
•
Dry
•
Temperature range -40°F to 158°F
(-40°C to 70°C)
Location requirements:
•
Solid foundation
•
Vibration free
•
Dry
•
Temperature range -40°F to 158°F
(-40°C to 70°C)
•
Do not remove any plastic coverings
•
Do not remove any plastic coverings
•
Do not remove any plastic coverings