MIU-1500 / CompuCount User’s Guide
Page 9
Error Message
Description
Offline
The MIU hasn't received a transmission from
this sensor within the timeout interval, which is
set in the "Manager Setup" screen under
"Sensor Offline Time."
Beam Blocked
The sensor beam seems to be blocked by some
obstruction.
Check Battery
The battery voltage is low or the battery is not
present.
No Line Power
Line power has been removed or is too low.
MIU Setup Options
The Status Screen
The status screen shows detailed information about
the sensors currently being monitored. To view the
status screen click on the "Status" link from the main
screen.
The status table shows, for each sensor, the
identifying label name of the sensor ("Sensor") , the
serial number of the sensor ("ID"), the number of
seconds elapsed since the last transmission ("Age"),
whether the last transmission was sent in service
mode or not ("Srv"), and the data value of the last
reading ("Last Reading"). The last reading is the accumulated count of the sensor since the sensor started or
since the last reset. If the transmission was sent in service mode, there will be an "X" in the "Srv" column.
When the MIU-1500 receives a transmission from a new sensor it assigns it a default label which is the sensor
position plus the sensor type ("1Count"). You can change the label assigned to the sensor by clicking on the label
name in the "Sensor" column.
The status table will highlight in yellow a row in the table if the sensor is in an error state. The browser will show
an error message when the mouse pointer is moved over top of the graphic symbol. The following table shows
the possible error states: