User Manual
THIS DOCUMENT IS UNCONTROLLED WHEN PRINTED
Page
26
of
34
7.9.
Safety sensor
The safety sensor is required when using product accessories such as the key pad, GSM phone
access or activation sensor ensuring the boom does not lower when the beam is broken. The safety
sensor is mounted to the product with the reflector mounted to a bollard which will be placed
opposite the sensor.
STEP 1
–
Unpack the accessory and check components:
•
Check the condition of the accessory to ensure all components have been supplied.
STEP 2
–
Attach accessory to the product:
•
Attach the safety sensor to the side of the unit as indicated in the picture.
•
The sensor it attached using a double sided adhesive tape.
•
Ensure that the sensor is level with the reflector bollard.
STEP 3
–
Connect accessory cable to connection port:
•
Ensure the product is turned off prior to connecting cable.
•
Connect cable and plug into the safety sensor (SS) connection socket.
•
Ensure plug is pushed in and fully connected.
STEP 4
–
Positioning the accessory:
•
Position the reflector bollard in close proximity to the product (radius no greater than 4m).
•
Ensure the reflector bollard is aligned opposite the sensor fitted to the product.
•
Ensure the safety sensor light turns green, if it turns red, realignment is required.
•
Ensure the bollard is on a flat surface and secured to the ground to prevent it from falling.
STEP 5
–
Test and operate accessory:
•
Access the control panel using the key.
•
Turn the safety sensor (SS) switch on by pressing the switch up.
•
Activate the product on by switching the power button on.
•
The product will run a self-test, once complete the green power light will illuminate.
•
Test attachment in manual mode by pressing the red button and using the remote control.
•
Obstruct/break the beam as the boom is lowering to test the safety bounce-back feature.