Trade-wind H3200 Series Installation Instructions & Use & Care Manual Download Page 3

 

 

Revised 6/11/18                              Copyright ©  2018  Trade-Wind Manufacturing, LLC                      Proverbs 22:29                        Page 3 

 

 

 

 

INSTALLATION INSTRUCTIONS & 

USE & CARE GUIDE 

Trade-Wind

®

 H3200 Series Range Hoods

 

 
 
 
 
 

H3200 Series 

 

Model 

 

Width(in.) 

 

CFM 

H32303RC 

30‖ 

390 

H32363RC 

36‖ 

390 

H32423RC 

42‖ 

390 

H32306RC 

30‖ 

600 

H32366RC 

36‖ 

600 

H32426RC 

42‖ 

600 

H32487RC 

48‖ 

780 

 

CONTENTS: 

 

Part 1 - Planning the Installation 
Part 2 - Electrical Connection 
Part 3 - Direction of Vent and  
             Securing The Hood 
Part 4 - Use & Care  

 
 
 
 
 
 
 
 
 

 
 
 

 
Before beginning installation, please thoroughly read and become familiar with these instructions.  Installation and 
service must be completed by a qualified installer.  Failure to properly install this product may void the warranty.

 

 

Installer:    Please leave Installation Instructions with the range hood owner.  

Owner:   

Please keep Installation Instructions for local electrical inspector’s use and for future reference.  

 

 
 

 
 
 
 
 
 
 

WARNINGS:  

Instructions must be followed carefully to avoid personal injury.

 

 
 

 
 
 
 
 
 
 

IMPORTANT:  

Must be followed carefully to avoid damage or incorrect installation. 

 
 

 
 
 
 
 
 
 

TIPS:  

Contain helpful information to facilitate installation. 

 

READ AND SAVE THESE INSTRUCTIONS 

 

          WARNING!  TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO   
           PERSONS OBSERVE THE FOLLOWING: 

a)  Use this unit only in the manner intended by the manufacturer.  If you have any questions, please contact the 
manufacturer at the address or telephone number listed in the warranty.  
 
b)  Before servicing or cleaning unit, switch power off at service panel and lock service panel and/or the service 
disconnection means to prevent power from being switched on accidentally.  When the service disconnecting 
means cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel. 
 

CAUTION

  

-- 

For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 

 

Summary of Contents for H3200 Series

Page 1: ...Revised 6 11 18 Copyright 2018 Trade Wind Manufacturing LLC Proverbs 22 29 Page 1 ATTENTION PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL...

Page 2: ...Revised 6 11 18 Copyright 2018 Trade Wind Manufacturing LLC Proverbs 22 29 Page 2...

Page 3: ...lectrical inspector s use and for future reference WARNINGS Instructions must be followed carefully to avoid personal injury IMPORTANT Must be followed carefully to avoid damage or incorrect installat...

Page 4: ...ns 1 Consult a licensed ventilation contractor or qualified technician for proper installation of exhaust ducting Locate the cooking area for minimum cross drafts away from doors and windows when poss...

Page 5: ...and duct runs should be as short as possible Where turns are necessary keep turning radius as large and as smooth as possible 7 The ducting must be air tight Use a minimum of 2 sheet metal screws at...

Page 6: ...ity to ensure that a qualified person performs the electrical connection of this appliance The electrical installation including minimum supply wire size must comply with the National Electric Code AN...

Page 7: ...ds removes more air from the inside of the house that must be replaced by outside air This may be especially costly when your home s heating or air conditioning system is in operation Turn off the uni...

Page 8: ...ly If you press the 5 minute delay auto off button again the blinking on the speed button stops and the blower has returned to manual mode If you would like to mount the remote to any surface near you...

Page 9: ...ating to improperly sized ducting or restrictive roof caps is not covered and will by default be charged back to the Homeowner Light bulbs are not covered under warranty Trade Wind Manufacturing LLC d...

Page 10: ...NOT use butt joints c For best air flow elbows and pipe size transition fittings should not be directly connected to one another Where possible always include at least 15 inches of straight pipe betw...

Page 11: ...se carefully crafted tightly wrapped Aluminum Foil Metal Duct Tape on all connections and physically view and test the damper blades to make certain they are opening and closing correctly Make sure th...

Page 12: ...p may be properly sized roof caps or wall caps with built in dampers must be made so that when the damper is fully open the actual open area of the final air path is equal to or greater than the disch...

Reviews: