Operators manual for the Pentruder 8 – 20HF IQ and Pentpak 427
Page 27
Tractive Support
Connecting to
remote control:
The power pack may be disconnected from the mains when the remote
control is connected. The multi pin connector must be in the correct
position with the notch pointing upwards for the clamping ring to close.
Power supply:
The power pack must be connected to a 5-pin 380 - 480 V 3-phase
supply with minimum 32 Amp fuses. A neutral is NOT needed other than
for the 230V single phase supply.
Connecting to mains:
The power pack is equipped with a 32 Amp receptacle. To use other
sizes than 32 Amp plugs an adaptor must be fitted.
The power pack may be electrically disconnected from the mains when
the power cords between the power pack and saw head are connected.
32 Amp 5-
pin Euro
standard
receptacle
230V (on a
400V supply)
max 10 Amp.
A neutral is
needed to
the 32 Amp
receptacle
for the 230V
to work.
10 Amp
automatic
fuse