![Tractive Pentpak 427 Operator'S Manual Download Page 10](http://html.mh-extra.com/html/tractive/pentpak-427/pentpak-427_operators-manual_1147719010.webp)
Operators manual for the Pentruder 8 – 20HF IQ and Pentpak 427
Page 10
Tractive Support
Warning!
A saw blade rotates at up to 60 m/s peripheral speed, i.e. over 200 km/hour (120
mph). The energy stored in such a blade is considerable, and it is always important that the
machine always is mounted according to the instructions given in this manual, and that the
blade guard
always
is fitted.
Warning!
Always check that the equipment is in faultless condition and that all functions are in
order before work is commenced.
Warning!
Never connect the power cord from power pack to the HF motor while the power
pack is switched on. Press at least one of the Emergency Stop buttons before the power cord is
connected to power pack and HF-motor.
Warning!
The power pack must always be switched off and the 32 Amp plug and cable
disconnected from the power pack before any kind of service or repair is commenced.
Warning!
Mounting and dismounting of the saw head may only take place when the saw head
is disconnected from the power pack by removing the power cord from the saw HF-motor and
the 24V DC cord to the feed and travel motors.
Warning!
Mounting and dismounting of the
blade guard and saw blade
may only take place
when the saw head is disconnected from the power pack by removing the power cord from the
saw HF-motor and the 24V DC cord to the feed and travel motors.
Warning!
Track brackets may only be mounted according to the instructions given in this
manual.
Warning!
To maintain the level of safety inherent in the design of this machine, only Tractive
original spare parts may be fitted. Tractive AB disclaims all responsibility for damages occurring
as a result of use of non original parts.
Important!
The power pack should preferably only be operated when it is put on its back with
the hour meter pointing upwards.
Important!
The power pack is water cooled and must be drained from water when the ambient
temperature is in the proximity of or below 0 degrees Celsius. To drain the power pack
completely in sub zero temperatures, switch off the blade motor, disconnect water supply,
switch on water on the remote and blow out all water with compressed air. Alternatively, if no
electric power is available, blow backwards with compressed air in the coupling going to the
saw head. The check valve in the water ON/OFF-valve will then open and the remaining water
in the power pack can then be blown out.
Important!
The transistor power modules in the power pack are water cooled and the water
pressure must therefore be limited to max 5 bar. The water supply may only be connected to
the short hose on the water ON/OFF-valve on the power pack. The quick disconnect couplings
may not be replaced with couplings that are not fully open when disconnected.
Important!
Connect the power pack only to Pentruder wall saws, Pentruder Wire Saws, drill
motors or any such equipment which has been manufactured or approved by Tractive AB.
Always check with your sales agent that the power pack is suited for the machine it is
connected to.