![Tractive Pentpak 427 Operator'S Manual Download Page 13](http://html.mh-extra.com/html/tractive/pentpak-427/pentpak-427_operators-manual_1147719013.webp)
Operators manual for the Pentruder 8 – 20HF IQ and Pentpak 427
Page 13
Tractive Support
Preparation and mounting of track feet and tracks
Bolts for fastening
:
The track feet and the tracks should be mounted in such a way that they
can not become detached when the machine is working, or at sudden
changes in load on the anchor bolts.
The track feet are designed to fit the track to the surface the machine will
work on. The feet must be fixed by means of M12 x 60 (1/2” x 2”) screws
of 10.9 quality, or better, using a thick washer and anchors of type HKD
M12 (1/2”) or equivalent. See picture below.
Warning! Hilti no longer recommends the use of their HKD anchors
for fastening wall saw track brackets. Use other reliable anchors of
the HKD type.
If the HKD anchors or other high quality expansion
anchors can not be fixed securely, the track feet must be securely fixed
with through bolts and large washers to achieve the required level of
safety.
Positioning of feet:
The track feet should preferably be mounted in the position shown in the
picture above. The distance from the edge of the feet to centre of cut is
then 128 mm (5”). The distance from anchor bolt to centre of cut is 200 +-
25 mm (8” +- 1”).
Borttaget:
Positioning of
feet