21
4.8.2 Lifting rope installation
Attention
!
When using a fall arrest device of the models
BLOCSTOP
®
BSA... first insert the lifting rope
between roll and rope guide of the sensor
arm from above (fig. 40)!
a)
Feed the wire rope as far as possible into the
wire rope entry (fig. 41).
b)
Press UP-button, and push in the wire rope, until
it starts to reeve itself automatically and exits at
the opposite side.
Attention
!
Never use DOWN button to install the wire
rope, the load limiting device will not function!
On three-phase motors: Turn the phase in-
verter of the plug for 180
(Fig. 41).
Ensure a clear rope exit (fig. 42)!
c)
If the wire rope does not reeve, check:
– Is the wire rope tip in good condition?
– Did you press the correct button?
Fig. 40
Fig. 42
UP
Fig. 41
Phase inverter
on CE-plug
Ensure a clear rope exit
Lifting rope
Release lever
Guiding
Ø
max.
2 Ø
safety catch
ferrule
thimble
Fig. 38
e) Attention!
Never use the TIRAK
®
wire rope for fixing a
load!
Never let the wire rope rub over sharp edges!
Always ensure a clear rope exit!
Always keep it lightly lubricated!
Use normally commercially available multi-pur-
pose grease; do not use lubricants containing
disulphide (e.g. Molycote
®
).
Important
!
If the anchoring point for the rope is above
the TIRAK
®
hoist, first anchor the rope and
then insert into the TIRAK
®
device.
Fig. 39
Applies
to all BSA
models.