M 6113 rev 1
–
01/2010
Please consult us for lifting pieces with an other temperature than the ambient
temperature
Fit the beam onto the tines correctly so that it abuts behind them.
Adhere to the hook load corresponding to the load of the beam.
Working temperature : -20° to +90°C.
COMPULSARY INSPECTIONS AND CHECKS
Maintenance inspections and operations must be performed by qualified and entitled
persons.
Check on start up (or starting back up): in compliance with the national regulations.
Compulsory periodical check in compliance with the national regulations. Recommended
at least every 12 months by TRACTEL SOLUTIONS SAS.
A thorough examination paying particular attention to any alteration of parts due to
an impact, corrosion, cracking or deformation must be conducted a minimum of
twice a year, every month in the case of heavy-duty use in an aggressive
atmosphere.
TRACTEL SOLUTIONS is at your disposal in order to conduct any regulatory check.
STORAGE AND MAINTENANCE
Maintenance inspections and operations must be performed by qualified and entitled
persons.
Regularly check the equipment is in perfect working order (before every use), in particular
the semi-automatic system and the pivoting pads.
Perform visual inspection before every use.
Any part with a defect must be replaced by a TRACTEL SOLUTIONS part.
The material has to be stored in an safe place, at ambient temperature
During the storage, the material has to be in a stable position without risks of tipping over.
On request, Tractel Solutions supplies appropriate storage supports
Any overloaded equipment must be immediately withdrawn from use.
6
Summary of Contents for PC1.5-150
Page 23: ...M 6113rev1 01 2010 NOTES ...