6 OPERATION IN SINGLE CONFIGURATION
Single configuration consists of using an assembly made up of one sensor and one display unit for
measuring and displaying the stress on the sensor. Depending on the userʼs requirements, the display
unit can either be attached to the sensor or be separated from it.
Unless otherwise ordered, the radio link-up between the sensor and the display unit is set definitively in
the factory before dispatch. After this, the radio link can be configured by the user to meet their
requirements (see Chapter 7: Operation in multiple configuration).
6.1 Commissioning
6.1.1 Enabling the sensor batteries
The 3 x 1.5 V "AA" batteries are installed in the factory.
Remove the insulating tab protruding from the battery compartment to enable them.
For future battery changes, refer to Chapter 9.2
6.1.2 Charging the display unit
The display unit is delivered with the power pack charged.
Afterwards, use the charger provided to charge the power pack.
Charging time: 3 h.
The display unit can be used during charging.
6.1.3 Turning on the sensor
6.1.4 Information provided by the sensor LED
Always turn on the sensor before turning on the display unit; otherwise the display unit
will not be able to establish the radio link.
The ON/OFF switch is actuated by pressing lightly at the centre of
the membrane.
On power up, the two red LEDs flash.
To switch off, press and hold the switch lightly for 3 seconds.
Sensor operating
MODE
Sensor LED flashing
Measures per second
Autonomy
Stop
Off
-
-
Standard
1 flash per second
4 per second
300 h
Standard slow
1 flash every 2 seconds
1 per second
500 h
Power saving
1 flash every 4 seconds
1 every 4 seconds
1000 h
Standby
1 flash every 8 seconds
-
3000 h
Peak load
2 flashes per second
32 per second
100 h
Batteries low
Same but one LED at a time
-
ON
OFF