![Tractel Dynafor LLX2 0.5 t Operation And Maintenance Manual Download Page 45](http://html.mh-extra.com/html/tractel/dynafor-llx2-0-5-t/dynafor-llx2-0-5-t_operation-and-maintenance-manual_1147575045.webp)
GB
9
2. SPECIFICATIONS
2.1 Sensor and Display Unit
A
B
C
D
E
F
G
h
i
j
Coplanar version
MODEL
LLX2
0.5 t
LLX2
1 t
LLX2
2 t
LLX2
3.2 t
LLX2
5 t
LLX2
6.3 t
LLX2
10 t
Disp.
Unit
Maximum capacity
t
0.5
1
2
3.2
5
6.3
10
All
Test load
t
0.75
1.5
3
4.8
7.5
9.6
15
-
Safety coefficient
Minimum 4
-
Precision
0,1 % according to ISO 376 . 21°C(I.P. 67 = 0,2%)
-
daN
0.5
1
2
3.2
5
6.3
10
-
Increment
daN
0.1
0.2
0.5
0.5
1
1
2
<-
Max. Display
daN 550
1100
2200
3500
5500
6900
11000
<-
Number height
mm
-
-
-
-
-
-
-
25
Autonomy
From 300 to 3000 h depending of functions
48 h
Radio scope
m
80 (in open field) (I.P. 67 = 60)
RF technology
2.4 Ghz
Weight
kg
2.300
3.350
6.45
0.180
IP Protection
I.P. 66 NEMA 4 (I.P. 67 option)
I.P. 54
Usafe
From - 20° to 40°C
Sensitivity to T°
0.05% per 10°C
Head material
Steel
-
Sensor material
Aluminium
Steel
-
Dimensions mm
See technical data sheet 2026
For information, the radio range measured in laboratory is 80 m (60 m for IP 67) when the front
side of the sensor or of the LLXt module is pointing toward the back side of the display unit.
Caution ! This range may differ depending on circumstances, in particular:
- presence of obstacles.
- electromagnetic interference.
- under certain atmospheric conditions.
If you have any trouble or if you have a specific utilisation, contact the Tractel
®