WARNING AGAINST HAZARDOUS OPERATIONS
ƒ
Never activate or deactivate the magnet lifter when thickness of the load doesn’t
correspond to the minimum values specified on the « practical tables for capacity
reduction » or on the signalling plate.
ƒ
Never release the lever freely. Always maintain a grip on the lever to its initial position.
ƒ
Never remove the lever in active position.
ƒ
Ensure the load is in a stable position before deactivating the magnet lifter.
ƒ
Never lift more than one plate at a time. Take particular care when lifting thin plates.
ƒ
Never leave a load unsupervised.
ƒ
Temperature of the load or/ and atmosphere must be between –20 and +80°C. (-20 to
+250°C for magfor II HT)
ƒ
Never lift dangerous, explosive or radioactive loads.
ƒ
Never lift loads which have non-attached charges on top.
ƒ
Never exceed weights or min / max dimensions specified in « technical specifications ».
ƒ
Never use a magnet lifter in aggressive, chemical or saline atmospheres.
ƒ
Never lift a load by installing the magnet lifter on the narrow or smallest side.
ƒ
Never install the magnet lifter with its longitudinal side on longitudinal direction of the
load.