Operation Instructions 

Power on 

Once the unit has been fully installed with all required bias-‘T’s channels and the alarm interface has 
been connected, power can be applied to the unit.  

During the power on sequence all the front panel indicators should be seen to go through a power on 
test [RED/GREEN/YELLOW] 

ALL connected Bias-‘T’ channel s will now go through their start up sequence, with the respective 
channel indicator going from yellow to green for all connected channels, if any indicators go RED this 
indicated a channel fault. 
 
The unit status indicator will be seen to be GREEN +short blink RED if there are no channels in a fault 
condition. [See: Table 3 Status Indicator] 

 

 

Momentarily press the reset switch after which the status light should be steady GREEN. 

Channel Fault Conditions 

A channel will be in a fault condition if the current drawn from the channel is outside the normal 
operational current [i.e. the current draw is too high or too low]. 

When a channel first enters a fault state the controller will try to reset the channel three times. If the 
fault will not clear then the channel will enter the FAULT state at which point the power is removed 
from the affected channel and the remote alarm interface will indicate a FAULT mode. A faulty channel 
is indicated by a RED channel indicator. 

The controller will try to reset a faulty channel on an hourly basis; the remote alarm interface will 
continue to will indicate a FAULT mode until all enabled channels are operating correctly. 

 

Persistent State 

Once a channel has been enabled, disconnecting the channel will result in a fault condition 

even if the 

power to the PDU is cycled. 

In order to disconnect a channel fully it is necessary to press the reset switch for more than 5 
seconds [status indicator will turn YELLOW], then release, at which point the channel status 
indicator will go OFF. 

Summary of Contents for radio design RD300 PDU

Page 1: ...tered In Scotland No 328828 Shipley Wharf Wharf Street Shipley West Yorkshire UK Tel 44 0 8452 770125 Fax 44 0 8452 770126 Email mail radiodesign eu Web www radiodesign eu Company Proprietary and Conf...

Page 2: ...echanical Installation 19 Rack Mounting The unit is primarily designed for 19 rack fitment using the included mounting screw set Un Mounted If no suitable mounting is available it is permissible to mo...

Page 3: ...de to the PDU in the following order 1 Earth connection 2 Connect Bias T 1 to 6 3 Connect alarm interface 4 Connect power Earth connection The front panel of the PDU has a 6mm Earth stud provided to e...

Page 4: ...2 of the interface cable PDU connector is not removed as this will result in the channel not being enabled Check The Connections to the BIAS T are not reversed Ensure that unused channel connections...

Page 5: ...PDU OFF Open circuit Short Circuit PDU ON Alarm Open circuit Short Circuit PDU ON No Alarms Short Circuit Open circuit N O normally open contact N C normally closed contact N O N C COM RAI 3 2 1 RD30...

Page 6: ...respect to PIN 2 Table 2 Power Connections shows the required connections for a positive or negative supply option The PDU is protected against reverse polarity connections but if the polarity is not...

Page 7: ...a TRAC company 99 438 Issue 05 Page 7 of 16 Connection Detail...

Page 8: ...be in a fault condition if the current drawn from the channel is outside the normal operational current i e the current draw is too high or too low When a channel first enters a fault state the contro...

Page 9: ...power cycle RED BLINK GREEN Output channel in alarm or NO channels enabled and unit has been through power cycle YELLOW This mode can only be reached by user intervention and indicates that the RESET...

Page 10: ...RED Channel is in fault condition Check each channel for fault indication Channel Indicator OFF but Bias T connected Link on connector between PINS 1 and 2 missing Fit link between pins 1 and 2 Chann...

Page 11: ...ut Isolation 1000v note 1 Outputs 6 Output Voltage 12v 1v Output Current per channel max normal operation 130ma Output protection Fully short circuit protected with auto re start Current window Alarm...

Page 12: ...a TRAC company 99 438 Issue 05 Page 12 of 16 Interface Drawings...

Page 13: ...a TRAC company 99 438 Issue 05 Page 13 of 16 Front Panel View...

Page 14: ...a TRAC company 99 438 Issue 05 Page 14 of 16 This page is intentionally blank...

Page 15: ...a TRAC company 99 438 Issue 05 Page 15 of 16 This page is intentionally blank...

Page 16: ...a TRAC company 99 438 Issue 05 Page 16 of 16 This page is intentionally blank...

Reviews: