a TRAC company
99-438 Issue 05
Page 10
of 16
Fault Finding
Table 5 Fault Diagnosis, may be used to diagnose common faults:
Table 5 Fault Diagnosis
Fault Condition
Possible Cause
Possible solution
Status Indicator OFF
No power to PDU
Apply power
Incorrect polarity of PDU power
Check polarity.
PDU Faulty
Try new unit
Status Indicator GREEN
but blinking RED
Normal state after power cycle
press reset to clear.
Status Indicator RED
Channel is in fault condition
Check each channel for fault indication.
Channel Indicator OFF,
but Bias-‘T’ connected
Link on connector between PINS
1 and 2 missing
Fit link between pins 1 and 2
Channel Indicator RED,
and BIAS-‘T’ connected.
Channel is in a fault condition
Press reset switch
Swap working channel with faulty
channel.
-
If fault follows the BIAS-‘T’
the fault is in the BIAS-‘T’ or
cable, check wiring.
-
If fault stays on the channel
PDU may be faulty.
Channel Indicator
RED, NO BIAS-‘T’
connected.
Channel was connected,
but has been
disconnected
Press reset switch for more
than 5 seconds [till status
indicator goes yellow]
Summary of Contents for radio design RD300 PDU
Page 7: ...a TRAC company 99 438 Issue 05 Page 7 of 16 Connection Detail...
Page 12: ...a TRAC company 99 438 Issue 05 Page 12 of 16 Interface Drawings...
Page 13: ...a TRAC company 99 438 Issue 05 Page 13 of 16 Front Panel View...
Page 14: ...a TRAC company 99 438 Issue 05 Page 14 of 16 This page is intentionally blank...
Page 15: ...a TRAC company 99 438 Issue 05 Page 15 of 16 This page is intentionally blank...
Page 16: ...a TRAC company 99 438 Issue 05 Page 16 of 16 This page is intentionally blank...