Hygiene Equipment
Designed for People
46
Routine maintenance TR Comfortline
Monthly maintenance:
- Monthly maintenance must be performed by On-site engineer or trained staff.
- Repeat Before every use and Daily maintenance.
- Make sure that the supply hoses for Hot- and Cold water are fitted correctly and do
not leak.
- Make sure that the power cord is in good condition and has no damages.
Thermostatic mixer:
- Exercise the mixer by moving the temperature control rapidly from cold to hot and hot back to cold several
times pausing at extreme.
- For maintenance of the thermostatic mixer, read manual from the supplier of the thermostatic mixer (manual
enclosed at delivery).
- If the bathtub is used in an area with hard water, ensure that the mixer cartridge and strainers are clean.
See instructions in the manual from the manufacturer of the thermostatic mixer (manual supplied at delivery).
This must be done by a qualified person.
- If you have a FMM9000E Antibactus thermostatic mixer, also read manual from the
manufacturer how to flush it and restore it correctly (manual enclosed at delivery).
- Contact your TR Equipment representative if you need new manuals.
Warning
Scalding risk when flushing with hot water!
Warning
Shower hoses on the TR Comfortline bathtub manage 60°C /140°F for 10 minutes.
Warning
Maintenance and/or repairs may only be carried out by the manufacturer or qualified staff
authorized by the manufacturer. Otherwise warranty expires immediately.