Before and during bathing
Anyone operating the Bath/Lifter must fully under-stand all proceedings be-
fore - during and after the entire bathing cycle (see operating manuals).
Preparing Tub
Press and hold control button (1) to lower the bathtub to it lowest posi-
A.
tion.
Close the drain plug (9) by turning the overflow drainage knob.
B.
Set foot rest (7) into position appropriate for the patient legs. Footrest is
C.
not used with TR´s Stretcher Lift.
Ensure that the whirlpool inlet screen (23) is in place
D.
Turn the whirlpool outlet jet (21), anti-clockwise to full open position
E.
Fill bathtub automatically by pressing the on/off control (2) once.
F.
Set and monitor fill water temperature with mixer (3) and thermometer (8)
G.
Note:
Always physically check water temperature before and during bathing.
Read operating manual for patient handling.
Showering
Lift the shower handle (11) on the right side on the panel with the white
A.
hose (10) and hold it over the tub, away from patient.
Start the patient shower by pushing the on/off control (4) once on front of
B.
the control panel.
Set the mixer (3) to desired temperature.
C.
Physically test water temperature and adjust the mixer to suit.
D.
Shower or rinse patient with shower spray handle.
E.
Stop showering by pushing the on/off control (4). Once and return handle
F.
to its bracket (12)
Note:
Shower handle shall not be held in the bath water while bathing.
Whirlpool
The water level shall cover the outlet jet (21).
A.
Adjust the jet (21) for desired flow direction: centred for perineal area; to
B.
either side for circular flow. Avoid placing the jet in a full upward position,
as this could cause the water to splash.
Make sure the whirlpool inlet screen (23) is not obstructed.
C.
With the patient in the bathtub, turn on the whirlpool unit by pushing the
D.
”ON-OFF” control button (5).
To adjust water flow direction, turn the whirlpool jet (21).
E.
Increase or decrease whirlpool stream by turning the air control (22).
F.
Turn the whirlpool unit off by pushing the “ON-OFF” control button (5).
G.
TR 900A
Height adjustable Autofill bathtubs
Quick Guide for TR 900A, -CA, -CWA