After installation of the device master file the device in the catalogue is at the following place:
PROFINET IO
-->
Additional Field Devices
-->
Encoders
-->
TR Linear_Magnetostriction
-->
TR PROFINET Linear
In the example, as PROFINET IO-Device a LA-46 with two magnets was connected to
the PROFINET network. Under the category "Module Slot 1" already one input module
"pos + velocity 6 byte I" is entered, which cannot be changed. The second input
module on slot 2 was entered manually:
Figure 11
: Configuration example with “LA46”
Please recognize that the position data + velocity for the first magnet have the
addresses 0..5. The addresses 6..11 are reserved for the second magnet, see figure
above.
In the tab
Properties --> Parameters
the device parameters can be adjusted:
Figure 12: Parameter setting