TPC PC2800 Operation Manual Download Page 7

 

 

 

environment. 

Note

: 

UT refers to the AC grid voltage before applying the test voltage

3: Product Structure and Installation 

3.1

 

Structure diagram: 

 

 

3.2

 

Installation procedure: 

3.2.1

 

Open-package Inspection 

Open  the  package,  and  check  whether  the  device  is  in  good  condition,  check  complement  of  unit,  spare 

parts  and  consumable  parts  according  to  the  packing  list.  If  you  have  any  questions,  please  contact  our 

distributor or our company directly. 

3.2.2

 

Installation 

 

1)

 

Move the machine to appropriate location on the flat solid floor and press on the brake at the bottom  

of wheel. 

2)

 

Install the free arm onto the mounting joint at the top of the box. 

3)

 

Install the suction cover onto designated spot as above picture shows. 

4)

 

Use one-phase AC 220V-50hz or other local power (220V 60hz, 240V 50hz, 110V 60hz) would be ok. 

 

3.3

 

Operation mode control 

Move the machine to appropriate location and press on the brake at the bottom of wheel, plug in the power 

cord, pull the free arm to an appropriate position according to the demand, switch on the power and device 

start to work. Suction power could be controlled through the knob on the control panel, turn off the power 

switch after use, pull back the free arm. 

This equipment has stepless knob, it can meet the needs for most operation when the knob is adjusted to the 

low power area (green area). If some surgery need larger flow, it can be adjusted clockwise, the maximum 

power is not recommended. 

Summary of Contents for PC2800

Page 1: ...ProClean Extra Oral Suction System Model PC2800 TPC 851 Lawson Street City of Industry Ca 91748 P 800 560 8222 www tpcdental com...

Page 2: ...1 Contents 1 Overview 2 2 Technical Specifications 4 3 Product Structure and Installation 6 4 Maintenance 8 5 Trouble shooting 8 6 Electric principle diagram 8 7 Disposing notes 9 8 Packing list 9...

Page 3: ...shock Before powering on this product please confirm that the power supply you provide can meet the input power information marked near the power input port of this product Do not share the socket wit...

Page 4: ...id the use of other highly sensitive instruments and equipment at the same time so as to avoid the equipment from being interfered by electromagnetic sources 1 4 4 Cleaning Please keep the environment...

Page 5: ...air 2 4 Electromagnetic Compatibility Medical electrical equipment requires special tips on electromagnetic compatibility as well as installation and use according to the electromagnetic compatibilit...

Page 6: ...t burst GB T17626 4 2kV On the power cord 1kV For input output lines 2kV On the power cord Not Applicable The grid power supply should have the quality used in a typical commercial or hospital environ...

Page 7: ...joint at the top of the box 3 Install the suction cover onto designated spot as above picture shows 4 Use one phase AC 220V 50hz or other local power 220V 60hz 240V 50hz 110V 60hz would beok 3 3 Oper...

Page 8: ...can effectively remove the droplets and aerosolparticles absorb water vapor Secondary Filter HEPA 13 filter it can effectively filter out 99 95 solid particles and colloidal substances Size 240 175 2...

Page 9: ...lamp once a year 4 4 ProClean Extra Oral Suction System When not in use store in a dry and ventilated place 4 5 Replacement Filters Items PC2800 SYNFLTR Replacement washable synthetic fiber filter PC...

Page 10: ...on cover pc 2 3 Instruction manual pc 1 7 Disposing notes Following requirements shall be followed as stored Disconnect the appliance from power The components of the product are non toxic dispose of...

Reviews: