Name
:
TPC ProClean Extra Oral Suction
Model
:
Model PC2800
Voltage/Frequency
:
AC 220V / 50
Power
:
1250W
Noise
:
≤
70dB
Suction rate / wind pressure
:
3000L/min
(
5KPA
)
Suction pressure: -10KPa
Dimensions
:
368.1*323.5*762MM (not including the free arm)
Filter level
:
HEPA 13
Filter efficiency:
≥
99.97%
2.2
Classification
2.2.1
Classified by type of anti-motor: Class I equipment
2.2.2
Classification by electric shock protection: ordinary equipment without application part
2.2.3
Classified according to the degree of protection against liquid ingress: IP20 equipment
2.2.4
According to the safety level when used in the case of anesthetic gas mixed with air or flammable
anesthetic gas mixed with nitrous oxide
Classification: Not AP type and APG type equipment
2.2.5
Classified by operating mode: intermittent operating equipment
2.3
Transport, storage and use conditions
2.3.1
Transport and storage
The machine should be transported and stored under following conditions: Temperature: -10
℃
~ + 50
℃
Relative humidity range:
≤
90%, atmospheric pressure range: 50 kPa ~ 106 kPa
2.3.2
Working condition
Temperature: + 5 ~ 40
℃
, relative humidity:
≤
80%, atmospheric pressure: 86kPa ~ 106kPa
There should not be a lot of dust and corrosive substances in the surrounding air.
2.4
Electromagnetic Compatibility
Medical electrical equipment requires special tips on electromagnetic compatibility, as well as installation
and use according to the electromagnetic compatibility information provided in the random files; portable
and mobile radio frequency communication equipment may affect the use of the equipment.
In order to ensure the best EMC performance, please use the specified cable. The AC power cord
specification is 1.8 meters in length; the transducers and cables sold by the company as spare parts for the
components of the internal active oxygen air disinfection machine. The use of accessories, transducers and
cables outside the regulations may cause an increase in the emission of the air disinfection machine or
reduced immunity.
The suction machine should not be used close to or stacked with other equipment. If it must be used close
to or stacked, it should be observed to verify that it can operate normally.
Guidance and manufacturer's declaration-electromagnetic emissions
Dental electric suction machine should be used in the specified electromagnetic environment, the user or
buyer should ensure that this product is used under such conditions.
Launch experiment
Compliance
Electromagnetic environment-guide
Radio frequency
emission
GB4824
One Unit
Dental electric suction machines use radio frequency
energy only for their internal functions. Therefore, its radio