TPC PC2800 Operation Manual Download Page 4

without authorization, and can only be repaired by the manufacturer or authorized service provider. 

 

Damaged power cord. 

 

The device does not work properly. 

 

The device is damaged. 

 

Water entered in the device. 

 

The device runs loudly or has a harsh sound, the output air is overheated, and an unpleasant odor 

is emitted. 

 

Product introduction, instruction manual, technical manual, product repair card, circuit diagram, 

parts  list  and  other  useful  information,  etc.,  need  to  be  provided  when  the  technician  of  an  

authorized service provider repair. 

6)

 

The operator should unplug the power plug when leaving. 

7)

 

In order to avoid damage to machinery and electrical appliances, prevent attachments from falling. 

8)

 

The disposal of wastes and residues of products shall comply with the requirements of relevant national 

environmental protection regulations. 

9)

 

Strong electromagnetic waves will not be generated during the operation of this product, but in order to 

ensure the normal use of other medical devices, it should be prepared for grounding or try to avoid the use 

of other highly sensitive instruments  and equipment at the  same time, so as to avoid the equipment from 

being interfered by electromagnetic sources. 

1.4.4

 

Cleaning 

Please keep the environment of the product clean. Before cleaning the product, please disconnect the power 

supply, wipe the outer surface of the product with a soft cloth and neutral detergent; ABS parts should be 

cleaned with a soft cloth dipped in soapy water; metal baking parts are cleaned with a soft cloth dipped in 

soapy water or wiped with car wax. 

Attention

Do not use liquid or cleaning agents containing flammable substances. 

 

1.5

 

Symbols and Marks 

During  installation,  operation  and  maintenance,  please  pay  attention  to  the  important  information 

represented by the symbols on the packaging and product labels: 

 

 

 

 

 

Fuse 

 

 

 

Attention, please refer to the instructions 

 

 

 

Protective grounding 

 

 

 

Turn On 

SN 

Serial number 

 

 

Turn off 

 

 

IP20 

(IP) Protection (2) The entry of 

foreign objects larger than 12.5 

mm in diameter and 0 (no 

protection against water) 

 

 

S3 30% 

Intermittent operation 

The ratio of operating time to the sum of 

operating time and subsequent interval 

time is 30% 

 

 

 

Fragile 

 

 

 

Face up 

 

 

 

Avoid moisture 

 

 

 

Stacking layers 

 

2.

 

Technical Specifications 

2.1

 

Technical Specifications: 

Summary of Contents for PC2800

Page 1: ...ProClean Extra Oral Suction System Model PC2800 TPC 851 Lawson Street City of Industry Ca 91748 P 800 560 8222 www tpcdental com...

Page 2: ...1 Contents 1 Overview 2 2 Technical Specifications 4 3 Product Structure and Installation 6 4 Maintenance 8 5 Trouble shooting 8 6 Electric principle diagram 8 7 Disposing notes 9 8 Packing list 9...

Page 3: ...shock Before powering on this product please confirm that the power supply you provide can meet the input power information marked near the power input port of this product Do not share the socket wit...

Page 4: ...id the use of other highly sensitive instruments and equipment at the same time so as to avoid the equipment from being interfered by electromagnetic sources 1 4 4 Cleaning Please keep the environment...

Page 5: ...air 2 4 Electromagnetic Compatibility Medical electrical equipment requires special tips on electromagnetic compatibility as well as installation and use according to the electromagnetic compatibilit...

Page 6: ...t burst GB T17626 4 2kV On the power cord 1kV For input output lines 2kV On the power cord Not Applicable The grid power supply should have the quality used in a typical commercial or hospital environ...

Page 7: ...joint at the top of the box 3 Install the suction cover onto designated spot as above picture shows 4 Use one phase AC 220V 50hz or other local power 220V 60hz 240V 50hz 110V 60hz would beok 3 3 Oper...

Page 8: ...can effectively remove the droplets and aerosolparticles absorb water vapor Secondary Filter HEPA 13 filter it can effectively filter out 99 95 solid particles and colloidal substances Size 240 175 2...

Page 9: ...lamp once a year 4 4 ProClean Extra Oral Suction System When not in use store in a dry and ventilated place 4 5 Replacement Filters Items PC2800 SYNFLTR Replacement washable synthetic fiber filter PC...

Page 10: ...on cover pc 2 3 Instruction manual pc 1 7 Disposing notes Following requirements shall be followed as stored Disconnect the appliance from power The components of the product are non toxic dispose of...

Reviews: