background image

 

 

11

5.2 Wireless Remote Controller   

 

Table 2: Functions of Each Keys of the Wireless Remote Controller 

Name Function 

ON/OFF button 

z

 

Press this button, the unit will be started or stopped, which can clear 
the timer or sleeping function of last time. 

- /+ button 

z

 

When press + button , the setting temp. will be increased by 
1   ,Wh

en press -button, the setting temp. will be decreased by 

1 The temp. will be changed quickly by pressing the button 

continuously and setting temp. range is 16~30

 

MODE button 

z

 

Press this button, Auto, Cool, Dry, Fan, Heat mode can be selected 
circularly. Auto mode is default while power on. Under Auto mode, 
the temperature will not be displayed; Under Heat mode, the initial 
value is 28 (82 );Under other modes, the initial value is 

25 (77 ).

 

 

 AUTO 

 COOL 

 DRY 

 FAN 

  HEAT (only for cooling and heating unit) 

SWING UP AND 

DOWN BUTTON 

z

 

Swing mode is defaulted for the wireless remote control. In this 
mode, press this button , could turn on or turn off the Up and down 
swing function. 

z

 

When unit is turned off, synchronously press "+" and Up and down 
swing buttons, it could be switched between the swing mode and 
stationary swing mode, at this time,   blinks 2 seconds. 

Summary of Contents for TGS-100FSA-E

Page 1: ...or Standing Indoor Unit Applicable models TGS 71FSA E TGS 100FSA E TGS 140FSA E Please read this manual carefully before using this product and keep it properly for future reference Installation and Operation Manual ...

Page 2: ......

Page 3: ...allation of the Baffle 5 3 5 Electrical Connection 5 Ⅳ WORKING TEMPERATURE RANGE 7 Ⅴ CONTROL 8 5 1 Control Panel 8 5 2 Wireless Remote Controller 11 5 3 Guides for General Operation 14 5 4 Introduction for Special Functions 14 5 5 Replacement of Batteries 15 5 6 Adjustment of Swing Directions 16 Ⅵ CARE AND MAINTENANCE 17 6 1 Cleaning the Unit 17 6 2 Cleaning the Air Filter 18 ...

Page 4: ......

Page 5: ...eat exchanger while preparing for the next operation And this is normal z When the selected operating mode of the indoor unit are clash with the operating mode of the outdoor unit the malfunction light will blink after 5s on the indoor unit or remote controller showing that the operation clash then the indoor unit will stop At this time change the operation mode of the indoor unit to the one that ...

Page 6: ...useful life of units may shortened z Do not mangle wire or adopts wires that are not recommend to use otherwise electric shock or fire may happen z Please don t operate the unit by wet hand or electric shock may happen z Don t insert finger or stick like things into outlet vent otherwise damage may happen z Cut down the main power switch immediately if malfunction such as smell the burning odor et...

Page 7: ... 5 A place full of machine oil 6 A place with sulphide gases such as sulphur spring 7 An environment with special conditions 3 1 2 Installation Location of Indoor Unit 1 select a place avoid the inflammable gas produce or leakage 2 Select a place avoid the water vapor or oil spayed on the unit 3 Ensure that airflow can reach every corner of the room 4 Choose a place so that the connection pipe cou...

Page 8: ...lease contact the local TOYOTOMI special nominated repair department before installation Any malfunction caused by the unit that is installed by the department that is not special nominated by TOYOTOMI would not deal with on time by the inconvenience of the business contact 3 It should be guide under the professional personnel when the air conditioner unit is moved to other place 3 3 Piping ...

Page 9: ... fix them with insulated tape 3 If the drainage pipe should be wrapped with heat preservation material at least 9mm thickness and then wrap it with tape to prevent air from entering into the pipe which will cause condensation 4 After connecting check if water can discharge properly or if there is any leakage As shown in Fig 5 3 4 Installation of the Baffle Fig 8 Please install it after installatio...

Page 10: ...een combustible surface and the air conditioner is 1 5 meters g The indoor unit and outdoor unit must be reliably earthed Models Power Supply Air switch capacity A Min sectional area of power cord mm2 core TGS 71FSA E 6 0 H05VV F 1 0 mm2 3 TGS 100FSA E 6 0 H05VV F 1 0 mm2 3 TGS 140FSA E 220 240V 50Hz 6 0 H05VV F 1 0 mm2 3 Notes Please pay attention to surrounding conditions eg Ambient temp direct ...

Page 11: ... cover Notes When the connection wire length isn t enough please contact with the appointed service shop for buying a dedicated electric wire with enough length the connection isn t allowed between the wire The wrong wiring connection isn t allowed it may cause the malfunction of the components Tighten the terminal screw After tightened the screw and slightly pull the electric wire to confirm whet...

Page 12: ...ndicates the cooling status DRY it indicates the dehumidifying status and the fan runs at the low speed FAN it indicates the fan status HEAT it indicates the heating status Note it is unavailable for the cooling only unit 3 Light It switches on off the lights expect the running and power indicating lights and 88 LBD 4 Function Under the On status of the unit it can switch functions among up down S...

Page 13: ...ptions Turbo On and Turbo Off i SET there are two options Set Temperature On and Set Temperature Off j Indoor Ambient Temperature there are two options Indoor Ambient Temperature On and Indoor Ambient Temperature Off k Energy Saving it is used to set the cooling lower temperature limit and heating upper temperature limit among 16 30 It is available to quit this function by press the keys Function ...

Page 14: ...tatus of the unit it is available to switch the host and slave status of the unit by pressing the key Mode for five seconds When 88 LED displays HO it indicates this indoor unit now is the host unit When 88 LED displays CH it is regarded as the slave unit as it has no valid host unit When 88 LED displays SL it indicates this indoor unit now is the slave unit 7 Enquiry of the unit status host or sl...

Page 15: ...0 MODE button z Press this button Auto Cool Dry Fan Heat mode can be selected circularly Auto mode is default while power on Under Auto mode the temperature will not be displayed Under Heat mode the initial value is 28 82 Under other modes the initial value is 25 77 AUTO COOL DRY FAN HEAT only for cooling and heating unit SWING UP AND DOWN BUTTON z Swing mode is defaulted for the wireless remote c...

Page 16: ...n set press this button once again to quit it TEMP display button z After powered on displaying presetting temperature is defaulted According to customer requirements to display if there are no requirements the presetting temperature displaying is defaulted there is no signal display on the remote control Press this button display display the presetting temperature display display indoor ambient t...

Page 17: ...to be Blow off This function can not be set under auto fan or heat mode and the characters of Blow won t appear LIGHT button z Press this button to select LIGHT on or off in the displayer When the LIGHT on is set the icon will be displayed and the indicator light in the displayer will be on When the LIGHT off is set the icon will be displayed and the indicator light in the displayer will be off LE...

Page 18: ...Press FAN button to set fan speed the AUTO FAN LOW MID or HIGH could be selected Press button and button to set swing mode Press SLEEP button set the sleep mode Press TIMER button then press button to set the scheduled timer on or timer off Press LIGHT button to control displayer light on or off Press BLOW button to set Blow function on or off Press TURBO button to set this function on or off 5 4 ...

Page 19: ...function is deactivated no BLOW will be displayed on the wireless remote controller 5 4 2About turbo function If start this function the unit will run at super high fan speed to cool or heat quickly so that the ambient temperature approaches the preset temperature as soon as possible 5 4 3 About lock Press and buttons simultaneously to lock or unlock the keyboard If the remote controller is locked...

Page 20: ...ignal 5 6 Adjustment of Swing Directions 5 6 1 Up Down Swing 1 up down swing motor by selected to control start or stop of up down swing motor by pressing up down button on remote controller or FUNC button on displayer so that guide louver will swing up and down or stop at a certain angle 2 If indoor fan has operated press up down button on remote controller Refer to remote controller instruction ...

Page 21: ...has operated press left right button on remote controller Refer to remote controller instruction for swing mode 3 Select left right swing button on displayer to set it and then press or button to start or stop swing Press it once to start and repress it to stop 4 If stop of swing is selected the characters and icon about up down swing will disappear When other states are selected characters and ic...

Page 22: ...g the air filter As shown in Fig 10 take out the decorative strip at position and unscrew the screw After opening the glass panel and unscrew the screws fixing the air filter At last pull out the air filter along the arrow direction 2 Cleaning the filter Slightly flat the filter or clean the filter with electric cleaner If there is too much dust on the filter clean it with a little neutral deterge...

Page 23: ......

Page 24: ...66129909116 ...

Reviews: