background image

ENGLISH

5

7. MAINTENANCE

Cleaning the Dehumidifier
To Clean the Body

Wipe it with a soft damp cloth.

To Clean the Air Filter

1. Open the inlet grill firstly and remove the air filter.

2. Clean the air filter

Run a vacuum cleaner lightly over the surface of the air filter to 
remove dirt. If the air filter is exceptionally dirty, wash it with 
warm water and a mild cleanser and dry thoroughly.

3. Attach the air filter

Insert the filter into the grill smoothly, and place the inlet grill into 
right place.

Storing the Dehumidifier

When the unit is not being used for a long period of time and you 
want to store it note the following steps:
1. Empty any water left in the drainage tank.
2. Fold up the power supply cord and put it in the water tank.
3. Clean the air filter.
4. Discard in a cool and dry place.

Clearance

Maintain the minimum clearance around the dehumidifier when the 
unit is operating as shown in the left drawing.

8. TROUBLESHOOTING

If a condition listed below occurs, please check the following items 
before calling customer service.

Problem

Possible Cause

Solution

The unit doesn’t 
operate

Has the power cord 
been 
disconnected?

Plug the power
cord into the outlet.

Is the tank full indi-
cation lamp blink-
ing? (The tank is full 
or in a wrong posi-
tion.)

Empty the water in 
the drainage tank 
and then reposition 
the tank.

Is the temperature 
of the room above 
35°C or below 7°C?

The protection de-
vice is activated 
and the unit cannot 
be started.

The dehumidifying 
function doesn’t 
work

Is the air filter 
clogged?

Clean the air filter 
as instructed under 
“Cleaning the dehu-
midifier”.

Is the intake duct or 
discharge duct ob-
structed?

Remove the ob-
struction from the 
discharge duct or 
intake duct.

No air is discharged Is the air filter 

clogged?

Clean the air filter 
as instructed under 
“Cleaning the dehu-
midifier”.

Operation is noisy

Is the unit tilted or 
unsteady?

Move the unit to a 
stable, sturdy loca-
tion.

Is the air filter 
clogged?

Clean the air filter 
as instructed under 
“Cleaning the dehu-
midifier”.

Summary of Contents for TD-C1416

Page 1: ...FTAVFUKTARE OSUSZACZ OPERATING MANUAL ENGLISH P 1 MANUAL D UTILISATION FRANÇAIS P 9 BEDIENUNGSANLEITUNG DEUTSCH P 17 GEBRUIKSAANWIJZING NEDERLANDS P 25 MANUALE DI ISTRUZIONI ITALIANO P 33 MANUAL DE INSTRUCCIONES ESPAÑOL P 41 MANUAL DE INSTRUÇÕES PORTUGUÊS P 49 BETJENINGSVEJLEDNING DANSK P 57 BRUKSANVISNING SVENSKA P 65 INSTRUKCJA OBSŁUGI POLSKI P 73 ...

Page 2: ...he appliances can be used indoor but not in laundry rooms 3 Do not set the unit close to heat gener ating devices or near flammable and dangerous materials 4 Never put your fingers or objects into the intake or discharge ducts 5 Do not sit or stand on the unit 6 Discard water that has collected in the tank as required 7 Do not operate the dehumidifier in a closed area such as inside a closet as it...

Page 3: ...e shall be compliance with national gas regulations Servicing shall be performed only as rec ommended by the manufacturer The appliance shall be stored so as to prevent mechanical damage from occur ring Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment authority which authorises their com...

Page 4: ...indoor air dry and comfortable Lightweight Portable Design The dehumidifier is built to be compact and lightweight The cast ers on the bottom of the unit make it easy to move from room to room Low Temperature Operation with Automatic Defrost When the unit is running in a room temp between 7 C and 12 C it will be stop to defrost for every 30 minutes When the unit is running in a room temp between 1...

Page 5: ...shutdown time from 1 to 24 hours Once turned on or off by user or entering water full state the unit may lost the timing function 4 DRAINING THE COLLECTED WATER When the drainage tank is full the tank full indicator light will turn on the operation will stop automatically and the buzzer will beep 15 times to alert the user that the water need to be emptied from the drainage tank 5 EMPTYING THE DRA...

Page 6: ...n in the left drawing 8 TROUBLESHOOTING If a condition listed below occurs please check the following items before calling customer service Problem Possible Cause Solution The unit doesn t operate Has the power cord been disconnected Plug the power cord into the outlet Is the tank full indi cation lamp blink ing The tank is full or in a wrong posi tion Empty the water in the drainage tank and then...

Page 7: ...e no live electrical components and wiring are ex posed while charging recovering or purging the system that there is continuity of earth bonding 9 Repairs to sealed components During repairs to sealed components all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to ...

Page 8: ...s sioned and emptied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 18 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only ap...

Page 9: ...ry in basis to your nearest autho rized dealer or distributor of TOYOTOMI WHAT YOU MUST DO FOR WARRANTY SERVICE You must return the defective Product or part to any authorized dealer or distributor of TOYOTOMI with this LIMITED WARRANTY If ser vice is not available locally please contact our CUSTOMER RELATIONS DEPARTMENT at TOYOTOMI EUROPE SALES B V E MAIL info toyotomi eu INTERNET www toyotomi eu...

Page 10: ... TOYOTOMI EUROPE SALES ITALY S R L VIA T EDISON 11 20875 BURAGO DI MOLGORA MB ITALY Email info toyotomi it http www toyotomi it TOYOTOMI EUROPE SALES SPAIN S A CALLE TRIGO 9 BAJO 2 28914 LEGANÉS MADRID SPAIN Email info toyotomi es http www toyotomi es TOYOTOMI FRANCE S A S LA CARTONNERIE RUE DU CANAL 27500 PONT AUDEMER FRANCE Email info toyotomi eu http www toyotomi eu New 03 20 Printed in P R C ...

Reviews: