Toyotomi TD-C1416 Operating Manual Download Page 4

ENGLISH

3

Meaning of crossed out wheeled dustbin. 

Do not dispose of electrical appliances as 

unsorted municipal waste, use separate 

collection facilities. Contact you local gov-

ernment for information regarding the col-

lection systems available. If electrical appli-

ances are disposed of in landfills of dumps.

Hazardous substances can leak into the 

groundwater and get into the foodchain, 

damaging your health and well-being.

This marking indicates that this 

product should not be disposed 

with other household wastes 

throughout the EU. To prevent 

possible harm to the environ-

ment or human health from uncontrolled 

waste disposal, recycle it responsibly to 

promote the sustainable reuse of material 

resources. To return your used device, 

please use the return and collection sys-

tems or contact the retailer where the 

product was purchased. They can take this 

product for environmental safe recycling. 

R290: 3

GENERAL

To obtain optimum performance from your dehumidifier, ensure 
that all windows are closed in order to achieve maximum efficien-
cy.
The capacity of the dehumidifier depends on the temperature and 
the humidity in the room, at lower temperatures less moisture will 
be removed.

FEATURES

Powerful Dehumidifying Capability

Taking advantage of refrigeration technology, the dehumidifier 
powerfully removes moisture from the air to decrease the humidity 
level of the room and keep the indoor air dry and comfortable.

Lightweight Portable Design

The dehumidifier is built to be compact and lightweight. The cast-
ers on the bottom of the unit make it easy to move from room to 
room.

Low Temperature Operation with Automatic Defrost

When the unit is running in a room temp. between 7°C and 12°C, it 
will be stop to defrost for every 30 minutes.
When the unit is running in a room temp between 12°C and 20°C, 
it will be stop to defrost for every 45 minutes.

Adjustable Humidistat

Adjust the desired humidity level by the humidistat.

Timer On / Off

Program the unit to turn on and off automatically.

Quiet Operation

The dehumidifier operates with a low noise level.

Energy Efficient

The power consumption of the unit is low.

1. DESCRIPTION

PARTS

1

2

4

3

5

7

6

1. Control Panel 

2. Handle 

3. Wind deflector

4. Caster 

5. Filter box 

6. Water tank

7. Supply code

OPTIONAL

1. Drainage hose

OPERATION PANEL

C

0

A

B

9

8 7

6

5

2

1

4

3

1.  Power button 

2.  Swing button

3.  Adjustment button 

4.  Timer button

5.  Setting button 

6.  Fan speed button

7.  Water full lamp 

8.  Power lamp

9.  Swing lamp 

10.  Timer/Set lamp

11.  High-fan lamp 

12.  Low-fan lamp

13.  Indication panel

2. OPERATION

Humidity Level & Timer 2 digit display

The indicator features 3 functions:

1. When the unit is turned on, it will indicate the room humidity lev-

el.

2. When you set the humidity, it will indicate the humidity that you 

have selected.

3. When you program the time for the unit to turn on and off, it will 

show the hours.

4. When the environment humidity is lower than 35%, it will show 

“35”.

5. When the environment humidity is higher than 95%, it will show 

“95”.

Summary of Contents for TD-C1416

Page 1: ...FTAVFUKTARE OSUSZACZ OPERATING MANUAL ENGLISH P 1 MANUAL D UTILISATION FRANÇAIS P 9 BEDIENUNGSANLEITUNG DEUTSCH P 17 GEBRUIKSAANWIJZING NEDERLANDS P 25 MANUALE DI ISTRUZIONI ITALIANO P 33 MANUAL DE INSTRUCCIONES ESPAÑOL P 41 MANUAL DE INSTRUÇÕES PORTUGUÊS P 49 BETJENINGSVEJLEDNING DANSK P 57 BRUKSANVISNING SVENSKA P 65 INSTRUKCJA OBSŁUGI POLSKI P 73 ...

Page 2: ...he appliances can be used indoor but not in laundry rooms 3 Do not set the unit close to heat gener ating devices or near flammable and dangerous materials 4 Never put your fingers or objects into the intake or discharge ducts 5 Do not sit or stand on the unit 6 Discard water that has collected in the tank as required 7 Do not operate the dehumidifier in a closed area such as inside a closet as it...

Page 3: ...e shall be compliance with national gas regulations Servicing shall be performed only as rec ommended by the manufacturer The appliance shall be stored so as to prevent mechanical damage from occur ring Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment authority which authorises their com...

Page 4: ...indoor air dry and comfortable Lightweight Portable Design The dehumidifier is built to be compact and lightweight The cast ers on the bottom of the unit make it easy to move from room to room Low Temperature Operation with Automatic Defrost When the unit is running in a room temp between 7 C and 12 C it will be stop to defrost for every 30 minutes When the unit is running in a room temp between 1...

Page 5: ...shutdown time from 1 to 24 hours Once turned on or off by user or entering water full state the unit may lost the timing function 4 DRAINING THE COLLECTED WATER When the drainage tank is full the tank full indicator light will turn on the operation will stop automatically and the buzzer will beep 15 times to alert the user that the water need to be emptied from the drainage tank 5 EMPTYING THE DRA...

Page 6: ...n in the left drawing 8 TROUBLESHOOTING If a condition listed below occurs please check the following items before calling customer service Problem Possible Cause Solution The unit doesn t operate Has the power cord been disconnected Plug the power cord into the outlet Is the tank full indi cation lamp blink ing The tank is full or in a wrong posi tion Empty the water in the drainage tank and then...

Page 7: ...e no live electrical components and wiring are ex posed while charging recovering or purging the system that there is continuity of earth bonding 9 Repairs to sealed components During repairs to sealed components all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to ...

Page 8: ...s sioned and emptied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 18 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only ap...

Page 9: ...ry in basis to your nearest autho rized dealer or distributor of TOYOTOMI WHAT YOU MUST DO FOR WARRANTY SERVICE You must return the defective Product or part to any authorized dealer or distributor of TOYOTOMI with this LIMITED WARRANTY If ser vice is not available locally please contact our CUSTOMER RELATIONS DEPARTMENT at TOYOTOMI EUROPE SALES B V E MAIL info toyotomi eu INTERNET www toyotomi eu...

Page 10: ... TOYOTOMI EUROPE SALES ITALY S R L VIA T EDISON 11 20875 BURAGO DI MOLGORA MB ITALY Email info toyotomi it http www toyotomi it TOYOTOMI EUROPE SALES SPAIN S A CALLE TRIGO 9 BAJO 2 28914 LEGANÉS MADRID SPAIN Email info toyotomi es http www toyotomi es TOYOTOMI FRANCE S A S LA CARTONNERIE RUE DU CANAL 27500 PONT AUDEMER FRANCE Email info toyotomi eu http www toyotomi eu New 03 20 Printed in P R C ...