Toyotomi TD-C1416 Operating Manual Download Page 5

ENGLISH

4

3. OPERATING INSTRUCTIONS

The buzzer will alarm for several times when the unit is powered 
on, the LED will show the room humidity for 3 seconds, then it will 
automatically turn off.
1. Turn on/off
 Press   to start the unit, when the unit is stop; or press 

 to 

shutdown it, when the unit is operating.

2. Humidity setting
  Press the 

 key to enter humidity-setting state, then press   

or   to adjust the humidity from 40% to 80%, every setting is 
5%, the LED flashing display when adjusting. Stop pressing for 
5 seconds, it will return to normal display. The default value of 
humidity is 55%.

3. Fan-speed setting
 Press   to set the fan speed to high or low, and the corre-

sponding fan speed light will be lighted.

4. Swing setting
  After the machine is started, press 

 to start or stop the air-

outlet leaf’s swing.

5. Time-setting
 Press   to enter boot-time setting state when the unit is stop, 

then the LED will display the time, you may press   or   button 
to adjust the automatic boot time from 1 to 24 hours. Press 

 

to enter shutdown-time setting state when the unit is running, 
then the LED will display the time, you may press   or   button 
to adjust the automatic shutdown time from 1 to 24 hours. Once 
turned on or off by user or entering water-full state, the unit may 
lost the timing function.

4. DRAINING THE COLLECTED WATER

When the drainage tank is full, the tank full indicator light will turn 
on,  the operation will stop automatically and the buzzer will beep 
15 times to alert the user, that the water need to be emptied from 
the drainage tank.

5. EMPTYING THE DRAINAGE TANK

1. Lightly press on the sides of the tank with both hands and pull 

the tank out gently.

2. Discard the collected water.

NOTE

1. If the drainage tank is dirty, wash it with cold or lukewarm water. 

Do not use detergent, scouring pads, chemically treated dust 
cloths, gasoline, benzene, thinner, or other solvents, as these 
can scratch and damage the tank and cause water leakage.

2. When replacing the drainage tank, press the tank firmly into 

place with both hands. If the tank is not positioned properly, the 
“TANK FULL” sensor will be activated, and the dehumidifier will 
not operate.

6. CONTINUOUS WATER DRAINAGE

The unit features a continuous drainage port. Using a plastic pipe 
(with an inner diameter of 10mm) inserts into drain hole (on inter-
mediate plate), reach out from side of water tank, install it in place, 
and arrange the drain pipe.
The water in the drainage tank can be continuously drained out 
from the continuous port on the unit.

Summary of Contents for TD-C1416

Page 1: ...FTAVFUKTARE OSUSZACZ OPERATING MANUAL ENGLISH P 1 MANUAL D UTILISATION FRANÇAIS P 9 BEDIENUNGSANLEITUNG DEUTSCH P 17 GEBRUIKSAANWIJZING NEDERLANDS P 25 MANUALE DI ISTRUZIONI ITALIANO P 33 MANUAL DE INSTRUCCIONES ESPAÑOL P 41 MANUAL DE INSTRUÇÕES PORTUGUÊS P 49 BETJENINGSVEJLEDNING DANSK P 57 BRUKSANVISNING SVENSKA P 65 INSTRUKCJA OBSŁUGI POLSKI P 73 ...

Page 2: ...he appliances can be used indoor but not in laundry rooms 3 Do not set the unit close to heat gener ating devices or near flammable and dangerous materials 4 Never put your fingers or objects into the intake or discharge ducts 5 Do not sit or stand on the unit 6 Discard water that has collected in the tank as required 7 Do not operate the dehumidifier in a closed area such as inside a closet as it...

Page 3: ...e shall be compliance with national gas regulations Servicing shall be performed only as rec ommended by the manufacturer The appliance shall be stored so as to prevent mechanical damage from occur ring Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment authority which authorises their com...

Page 4: ...indoor air dry and comfortable Lightweight Portable Design The dehumidifier is built to be compact and lightweight The cast ers on the bottom of the unit make it easy to move from room to room Low Temperature Operation with Automatic Defrost When the unit is running in a room temp between 7 C and 12 C it will be stop to defrost for every 30 minutes When the unit is running in a room temp between 1...

Page 5: ...shutdown time from 1 to 24 hours Once turned on or off by user or entering water full state the unit may lost the timing function 4 DRAINING THE COLLECTED WATER When the drainage tank is full the tank full indicator light will turn on the operation will stop automatically and the buzzer will beep 15 times to alert the user that the water need to be emptied from the drainage tank 5 EMPTYING THE DRA...

Page 6: ...n in the left drawing 8 TROUBLESHOOTING If a condition listed below occurs please check the following items before calling customer service Problem Possible Cause Solution The unit doesn t operate Has the power cord been disconnected Plug the power cord into the outlet Is the tank full indi cation lamp blink ing The tank is full or in a wrong posi tion Empty the water in the drainage tank and then...

Page 7: ...e no live electrical components and wiring are ex posed while charging recovering or purging the system that there is continuity of earth bonding 9 Repairs to sealed components During repairs to sealed components all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to ...

Page 8: ...s sioned and emptied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 18 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only ap...

Page 9: ...ry in basis to your nearest autho rized dealer or distributor of TOYOTOMI WHAT YOU MUST DO FOR WARRANTY SERVICE You must return the defective Product or part to any authorized dealer or distributor of TOYOTOMI with this LIMITED WARRANTY If ser vice is not available locally please contact our CUSTOMER RELATIONS DEPARTMENT at TOYOTOMI EUROPE SALES B V E MAIL info toyotomi eu INTERNET www toyotomi eu...

Page 10: ... TOYOTOMI EUROPE SALES ITALY S R L VIA T EDISON 11 20875 BURAGO DI MOLGORA MB ITALY Email info toyotomi it http www toyotomi it TOYOTOMI EUROPE SALES SPAIN S A CALLE TRIGO 9 BAJO 2 28914 LEGANÉS MADRID SPAIN Email info toyotomi es http www toyotomi es TOYOTOMI FRANCE S A S LA CARTONNERIE RUE DU CANAL 27500 PONT AUDEMER FRANCE Email info toyotomi eu http www toyotomi eu New 03 20 Printed in P R C ...