background image

1

SUMMARY

The idea behind the unit is to provide a localized supply of cool air.

The unit will greatly enhance your personal comfort whether at a
work station or even in your favorite chair.

Four (4) casters enable you to move the unit easily from room to
room. It cools and dries the air at the same time so that you can
stay comfortable even when it's humid or rainy outside. Also your
furnishings and fabrics are kept in good condition when it's used
as dehumidifier.

Conventional air conditioners use large quantities of energy to cool
an entire room, including walls and furniture. This unit creates a
zone of cool and dry air only where it is needed. It does not waste
energy cooling the surroundings.

It's easy to operate. The built-in timer allows from 1 to 24 hours of
operation, which will automatically turn the unit on and off. This is
especially convenient at bedtime.

Venting is not required. However, if the unit is to be used exclu-
sively in one space, the cooling efficiency will be enhanced by us-
ing the venting kit accessory, which is included with the uit.

OPERATIONAL FEATURES

1.

COOLING OPERATION:

Normally, cool air is directed out the front louvers by the circu-
lation fan which has three (3) stages of fan speed.

2.

HEATING OPERATION:

Warm air is directed out the air outlet grille by the circulation
fan which has three (3) stages of fan speed.

3.

THERMO CONTROL

The compressor will automatically shift to ON or OFF to main-
tain the desired temperature.

4.

TIMER OPERATION:

The unit will turn on and off after the designated period of time
(1, 2, 3, ...24 hours).

5.

AUTOMATIC SHUT-OFF MECHANISM WHEN THE
DRAIN TANK IS FULL:

When the drain tank is full, the unit will be automatically shut
off. The warning lamp will light. It is always required to press
the power button twice to resume operation after the con-
densed water is removed from the tank.

6.

AIR FILTER:

A pre-filter protects the unit from dust.

1. DESCRIPTION

Fig. A

FRONT

A1

Air outlet

A2

Vertical louver

A3

Front panel

A4

Operation panel

A5

Carrying handle

A6

Caster

Fig. B

REAR

B1

Air intake (Evaporator)

B2

Air intake opening

B3

Air intake (Condenser)

B4

Power supply cord

B5

Power plug

B6

Drain water outlet

B7

Air outlet opening

Fig. C

OPERATION PANEL

C1

Power button

C2

Mode button

C3

Fan speed button

C4

Timer button

C5

Adjust buttons

C6

Warning lamp (Tank full)

C7

Cooling mode lamp (green)

C8

Dehumidifying mode lamp (orange)

C9

Heating/Fan mode lamp (red/yellow)

C10 Room temp lamp
C11 Set temp lamp
C12 Timer operation lamp
C13 Digital indicator

Fig. I

DUCT SET

I1

Duct hose adapter nozzle (4 pcs.)

I2

Duct hose (2 pcs.)

Fig. J

WINDOW PANEL KIT

J1

Window panel “C”

J2

Window panel extension (2 pcs.)

J3

Duct hose grille (2 pcs.)

J4

Cover (2 pcs.)

J5

Screws

2. SAFETY TIPS

IMPORTANT

¡

Read instructions carefully before operation.

¡

The unit should be operated when the room temperature is
between 64˚F (18˚C) to 95˚F (35˚C). If the room temperature is
below 64˚F (18˚C), ice may form on the coils. If the room tem-
perature is above 95˚F (35˚C), the compressor will automatical-
ly shut off to protect itself.

¡

ALWAYS, wait 3 min. to restart after turning unit off.

WARNING

¡

NEVER expose infants, handicapped persons, or senior per-
sons directly to the airflow. Adjust the airflow direction.

¡

Keep children away from unit. Children are particularly liable to
this danger. The inside fan is running at high speed. Covering
them may deteriorate air conditioner performance or cause it
to become inoperative.

¡

NEVER insert objects of any kind into the air intake or air out-
let.

¡

DO NOT unplug if your hands are wet. An electrical shock may
occur.

¡

DO NOT operate in a wet location.

¡

ALWAYS plug into 115 V, 60 Hz, single phase electrical outlet.

¡

Be sure the power plug fits the receptacle securely.

¡

DO NOT run power cord under carpets, rugs, or floor mats of
any kind.

¡

DO NOT attempt to shorten or alter power cord in any way.

¡

DO NOT apply any excessive force or pressure to the power
supply cord.

¡

Make sure that the plug is free of dust.

¡

DO NOT use an extension cord.

¡

DO NOT turn on and off by inserting or removing the power
plug which may cause electric shock or fire.

¡

If there is a fear of lightning, stop the unit and disconnect the
power supply cord.

¡

DO NOT touch the evaporator, condenser and pipes.

¡

DO NOT operate with filter removed. 

CAUTION

¡

Keep unit more than 20 in. (50 cm) away from any objects or
wall. (Fig. D)

¡

If the unit is operated in COOLING mode in an area of very
high moisture, the top plate and the rear plate may get cov-
ered with a mist. Wipe off any mist before it has a chance to
get on the floor or rug.

¡

Remove drain water before moving unit.

¡

To minimize corrosion, DO NOT use in damp, salty air area.

¡

DO NOT operate in direct sunlight.

¡

DO NOT use for such particular purpose as preservation of
foodstuff, animals, plants, precision appliances, arts and med-
icine.

¡

DO NOT place an animal, plants or combustion equipment in
a place which is subjected to the direct air flow of the unit.

¡

DO NOT ride or place the objects on the unit.

¡

DO NOT turn the unit on its side or upside down.

ENGLISH

TAD-T40LW_US_ES_FR.qxd  14.7.18 14:12  ページ 1

Summary of Contents for TAD-T40LW-R

Page 1: ...BLE AIR CONDITIONER ACONDICIONADOR DE AIRE PORTATIL CONDITIONNEUR D AIR DEPLACABLE INSTRUCTION MANUAL ENGLISH P 1 MANUAL DE INSTRUCCIONES ESPA OL P 5 MODE D EMPLOI FRANCAIS P 9 TAD T40LW_US_ES_FR qxd...

Page 2: ...ed Down Timer B1 B7 B2 B3 B4 B6 B5 A1 A3 A6 A5 A4 A2 F1 C3 C1 C2 C5 C5 C4 C1 C2 C7 C8 C9 C6 C3 C5 C4 C11 C12 C13 C10 more than 20 in 50cm more than 20 in 50cm I1 I2 J3 J2 J1 J3 J4 J4 J5 J2 J5 PA NO 1...

Page 3: ...2270865 22740480 22740851 22740845 22740873 22740874 22740804 22740876 22740449 22740254 22740253 22740252 22740481 22740894 20740898 Base pan assembly Caster Float Micro switch Drain motor Blade 4 w...

Page 4: ...ow C10 Room temp lamp C11 Set temp lamp C12 Timer operation lamp C13 Digital indicator Fig I DUCT SET I1 Duct hose adapter nozzle 4 pcs I2 Duct hose 2 pcs Fig J WINDOW PANEL KIT J1 Window panel C J2 W...

Page 5: ...ay is room temperature When or button is pressed the set temperature is displayed and may be adjusted After 15 seconds the display will revert back to room temperature By pressing both buttons at once...

Page 6: ...hat the panel is extended so that screws do not go into sliding portion of panel 3 ENGLISH A hissing noise or hollow sound A squeaking noise Odor The unit does not start nor change operation mode im m...

Page 7: ...ilure to install operate or maintain unit in ac cordance with instructions operating and maintenance instruc tions are furnished with each new unit unreasonable use acci dents alteration use of unauth...

Page 8: ...C12 Luz de operation del timer C13 Indicador digital Fig I JUEGO DEL CONDUCTO I1 Tobera del adaptador de la manguera del conducto 4 pzas I2 Manguera del conducto tubo flexible 2 pzas Fig J KIT DEL PA...

Page 9: ...ar de modo refrigeraci n o deshumificaci n a modo calefacci n o a la inversa Modalidad FAN ventilador C9 Cuando el modo de Ventilador se selecciona la luz amarilla se enciende La modalidad FAN s lo pr...

Page 10: ...atr s so bre la unidad trasera la cual se ensamblar sobre la hendidura S 7 ESPA OL Silbido o ruido sordo Chirrido Olores La unidad no arranca ni cambia inmediatamente de modalidad de operaci n e Produ...

Page 11: ...t n libres de defectos en material y mano de obra bajo empleo y servicio normales por un per odo de DOCE 12 MESES a partir de la fecha de la entrega al comprador original sujeto a los sigu ientes t rm...

Page 12: ...l Fig I TUYAUTERIE DE CONDUITE I1 Buse d adaptation du tuyau de conduite 4 pi ces I2 Tuyau de conduite 2 pi ces Fig J KIT PANNEAU FENETRE J1 Panneau de la fen tre C J2 Extension du panneau de la fen t...

Page 13: ...st s lectionne la lampe jaune s allume Le mode FAN permet seulement la circula tion de l air de la pi ce et vous ne pouvez donc pas r gler la temp rature de la pi ce 3 APPUYEZ SUR LES BOUTONS DE REGLA...

Page 14: ...bruit provient du liquide de re froidissement s coulant dans les conduites e Ce bruit provient de l unit lors de dilatation ou de contraction avec les changements de temp rature e Des substances tell...

Page 15: ...OTOMI CO LTD TOYOTOMI garantit tous ses produits et pi ces en vente exempts de d fauts mat riels ou vices de fabrication dans des conditions d utilisation normales durant une p riode de DOUZE 12 MOIS...

Page 16: ...INS MA MO Printed in China Rev 07 14 Part No 22740894 TOYOTOMI CO LTD 5 17 Momozono cho Mizuho ku Nagoya 467 0855 Japan www toyotomi jp TAD T40LW_US_ES_FR qxd 14 7 18 14 12 a...

Reviews: