background image

4

8. TROUBLESHOOTING

BEFORE CALLING FOR SERVICE

The following are not defects.

9. SPECIFICATIONS

NOTE:

Cooling capacity will vary according to temperature and
humidity of the room.

10. VENTING KIT ACCESSORIES

If the unit is to be used exclusively in one space, the cooling ef-
ficiency will be enhanced by using the following venting kit ac-
cessories.

EXHAUST DUCT SET (FLEXIBLE TUBE) (Fig. I)

2 pcs.
Max. 4 ft. (1.2 m)

WINDOW PANEL KIT "C" (Fig. J)

Window panel kit "C"
For sliding and double-hung windows
Max. 37 in. (94 cm)
Min. 28-1/4 in. (72 cm)

USING EXHAUST DUCT SET (Fig. I)

1. Extend one-side ends of the exhaust

duct hose (flexible tube) (I2) around 4
in. (100mm).

2. Insert both ends of exhaust duct hose

(flexible tube) (I2) into exhaust duct
hose adapter nozzles (I1) by twisting
clockwise until it stops.

3. Fix one of the exhaust duct hose adapter noz-

zles onto the rear outlet of the unit. This is
completed by sliding the exhaust duct hose
adapter nozzle of the hose downwards over
the exhaust outlet of the unit, which will be
assembled with the grooves on the connector
of the unit. (B5 or B9)

4. Extend the exhaust duct hose (I2) and close the window or

door as far as possible trapping the exhaust duct hose
adapter nozzle (I1).

NOTE:

Place the unit as close as possible to the window or
door.

USING WINDOW PANEL KIT (Fig. J)
NOTE:

Window installations are possible by the use of the ex-
haust duct set and window panel kit.
In case of twin duct type, always use the window panel
kit "C".

1. Fix the exhaust duct hose grille (J3) to the window panel

with four (4) screws. Make sure that the panel is extended so
that screws do not go into sliding portion of panel.

ENGLISH

MODEL

TAD-T32JW

COOLING CAPACITY

12,000 BTU/H

HEATING CAPACITY

11,000 BTU/H

DEHUMIDIFYING CAPACITY

0.58 gal/h (2.2 L/H)

POWER SOURCE

Single Phase 115V, 60Hz

POWER CONSUMPTION

1,200 W (Cooling), 1,050 W (Heating)

OPERATING CURRENT

10.5 A (Cooling), 9.5 A (Heating)

AIR FLOW (MAX.)

250 CFM (425 m

3

/h)

OPERATING TEMP. RANGE

64˚F~95˚F (18˚C~35˚C)

DIMENSIONS (W

× 

H

× 

D)

20" 

×

36" 

×

16-1/2"

(508 

×

915 

×

418 mm)

WEIGHT

84 Lbs. (38 kg)

COMPRESSOR

ROTARY

REFRIGERANT

R-410A

A hissing noise or hollow
sound :

A squeaking noise :

Odor :

The unit does not start nor
change operation mode
immediately :

Blue LED flashes :

e

This sound is generated from
the refrigerant flowing within
pipes.

e

This noise is generated from the
unit when it is expands or con-
tracts with temperature changes.

e

Such odor as tobacco, cosmetics,
or foods may accumulate in the
unit.

e

To prevent overloading the com-
pressor motor, the unit will be
stopped for more than 3 minutes.

e

See “Filter Cleaning Indicator”,
Page 3.

4 in.

SYMPTOM

Unit does
not work.

Unit sud-
denly stops
during in
operation.

Unit runs in-
termittently.

Unit func-
tions but the
room is not
cooled.

Condensed
water is
spilled out
when mov-
ing the unit.

CAUSE

- Power cut.

- The plug has been

plugged inproperly.

- The full-tank indicator

is ON. Tank is full.

- Current leaking or

pressing test button
of LCDI plug.

- The indoor tempera-

ture has reached the
set temperature level.

- The preset time is up.
- The full-tank indicator

is ON. Tank is full.

- Malfunction.
- Surrounding temper-

ature is too high or
too low.

- Exhaust duct hose is

blocked.

- Window or door is

left open in the room.

- There is heat source

in the room or too
many of people in it.

- Air intake grille is

clogged.

- Filter is too dirty.
- Temperature setting

is too high.

- The tank is nearly full.

SOLUTION

- Wait for power to be

supplied again.

- Plug in again.

- Remove the drain

water from the drain
tank.

- Press reset button af-

ter solving the prob-
lem.

- Reset the tempera-

ture level.

- Reset the timer.
- Remove the drain

water from the drain
tank.

- Contact your dealer.

- Check the duct hose.

- Close all windows

and door.

- Move out any heat

source in the room.

- Clean the air intake

grille.

- Replace the filter.
- Lower the tempera-

ture setting.

- Remove the drain

plug on the rear bot-
tom of the unit, drain
off the water then the
unit will be in opera-
tion automatically.

TAD-T32JW  (GB/ES/FR)    10.6.17  8:59  AM    ページ 4

Summary of Contents for TAD-T32JW

Page 1: ...BLE AIR CONDITIONER ACONDICIONADOR DE AIRE PORTATIL CONDITIONNEUR D AIR DEPLACABLE INSTRUCTION MANUAL ENGLISH MANUAL DE INSTRUCCIONES ESPA OL MODE D EMPLOI FRANCAIS P 1 P 8 P 15 TAD T32JW GB ES FR 10...

Page 2: ...F1 F2 J3 J2 J1 J3 J4 C1 C6 C7 C8 C9 C2 C3 C4 J4 B8 B9 B1 B2 B3 B4 B5 B6 B7 B11 B10 C5 J5 J2 J5 I1 I2 Symbols Cooling mode High speed Dehumidify mode Fan only mode Auto mode Medium speed Low speed Hea...

Page 3: ...4 Down button C5 LCD display C6 Clock button C7 Timer button C8 C F toggle button C9 UP button C10 Fan speed indicator C11 Mode indicator C12 Launch signal indicator C13 Clock indicator C14 C F indica...

Page 4: ...CLOCK button C6 again to confirm the set ting LCD CLOCK display stops flashing 3 TEMPERATURE DISPLAY By pressing C F toggle button C8 the display will toggle between Celsius and Fahrenheit LCDI Leakag...

Page 5: ...ssary please replace the air filters Default Indicator When default indicator lights on internal wiring failure 1 Upper part Blue 2 Lower part Blue If get above 2 failures please contact your dealer 4...

Page 6: ...ling 9 5 A Heating AIR FLOW MAX 250 CFM 425 m3 h OPERATING TEMP RANGE 64 F 95 F 18 C 35 C DIMENSIONS W H D 20 36 16 1 2 508 915 418 mm WEIGHT 84 Lbs 38 kg COMPRESSOR ROTARY REFRIGERANT R 410A A hissin...

Page 7: ...installa tion in sliding windows Removing Exhaust duct set Fig I 1 Twist the exaust duct hose adapter nozzles I1 clockwise to remove the exhaust duct hose adapter nozzles I1 from the grooves on the c...

Page 8: ...2740253 22740252 22740481 22740676 22740677 22740255 22740695 22740699 22740490 22740483 22740482 Base pan assembly Caster Float Micro switch Drain motor Blade Compressor Rear fan motor Rear fan Capac...

Page 9: ...rn the defective Product or part to any authorized dealer or distributor of TOYOTOMI with this LIMITED WAR RANTY and a copy of your bill of sale or credit card charge receipt or other document evidenc...

Page 10: ...C F C9 Bot n de subida C10 Indicador de velocidad del ventilador C11 Indicador de modo C12 Indicador de se al de inicio C13 Indicador del reloj C14 Indicador C F C15 Indicador de temp fijada C16 Indi...

Page 11: ...el bot n de bajada C4 Cada segun do que mantenga presionado el reloj en el cristal l quido avanza a intervalos de 1 minuto Presione el bot n de subida C9 o el bot n de bajada C4 y mantenga presionado...

Page 12: ...de conexi n ON Timer Destella el LED azul Tanque de agua lleno Si el tanque de agua est lleno destella el indicador LED rojo Cuando el tanque de agua est lleno la unidad deja de fun cionar Despu s de...

Page 13: ...miento 1050 W Calefacci n CORRIENTE DE FUNCIONAMIENTO 10 5 A Enfriamiento 9 5 A Calefacci n FLUJO DE AIRE M X 250 CFM 425 m3 h GAMA DE TEMP DE FUNCIONAMIENTO 64 F 95 F 18 C 35 C DIMENSIONES An Al Prof...

Page 14: ...a la in stalaci n vertical en ventanas deslizantes Retirada del Juego de Conductos de Escape Fig I 1 Gire las toberas adaptadoras de la manguera conducto del escape l1 en direcci n a las agujas del re...

Page 15: ...ador trasero Ventilador trasero Condensador A Trasero Motor de ventilador delantero Ventilador delantero Condensador B Delantero Tarjeta de circuitos principal Condensador C Circuito de la luz indicad...

Page 16: ...izado de TOYOTOMI junto con esta GARAN TIA LIMITADA y una copia de su boleta de compra boleta de la tarjeta de cr dito o cualquier otra prueba fehaciente de compra y de la fecha de entrega del product...

Page 17: ...l horloge C14 Indicateur C F C15 Indicateur de r glage de la temp rature C16 Indicateur de r glage de la minuterie C17 Indicateur ON OFF de la minuterie Fig I TUYAUTERIE D EVACUATION I1 Canule adaptat...

Page 18: ...clignoter 3 AFFICHAGE DE LA TEMPERATURE En appuyant sur le bouton de s lection C F C8 l af fichage commute entre Celsius et Fahrenheit PRISE LCDI D tection du courant de fuite et arr t B11 TEST LORS...

Page 19: ...clig note dans l interrupteur ON OFF d urgence Affich seule ment pendant le mode de fonctionnement ATTENTION Lorsque la LED bleue commence clignoter sur Interrupteur ON OFF d urgence l avant de l appa...

Page 20: ...tion avec les changements de temp rature e Des substances telles que du tabac des produits cosm tiques ou des produits alimentaires peu vent s accumuler dans l unit e Pour emp cher toute surcharge du...

Page 21: ...le pour des fen tres coulissantes D montage de la gaine Fig I 1 Tournez les canules adaptatrices pour le tuyau de la gaine d vacuation l1 dans le sens des aiguilles d une montre pour retirer les canul...

Page 22: ...e Pale Compresseur Moteur du ventilateur arri re Ventilateur arri re Condensateur A Arri re Moteur du ventilateur avant Ventilateur avant Condensateur B Avant Circuit imprim principal Condensateur C C...

Page 23: ...ez retourner les produits ou pi ces d fectueux un agent agr ou dis tributeur TOYOTOMI accompagn s par cette GARANTIE LIMITEE et la copie de la facture ou le re u du d bit de votre carte de cr dit ou t...

Page 24: ...I M M TOYOTOMI CO LTD 5 17 Momozono cho Mizuho ku Nagoya 467 0855 Japan New 05 10 Part No 22740695 Printed in P R C TAD T32JW GB ES FR 10 6 17 8 58 AM a...

Reviews: