background image

17

PARTS LIST

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

22740429

22740270

22740230

22740206

22740422

22740223

22740413

22740420

22740442

22740446

22740418

22740441

22740447

22740412

22740448

22740417

22740427

22740435

22740451

22740445

22740403

22740440

22740443

22740428

22740444

22740480

22740449

22740254

22740253

22740252

22740481

22740476

22740255

22740460

22740266

22740461

22740269

22740271

22740462

22740463

22740274

22740267

22740464

22740495

22740494

22740499

22740498

Base pan assembly

Caster

Float

Micro switch

Drain motor

Blade

Compressor

Rear fan motor

Rear fan

Capacitor A(Rear FM)

Front fan motor

Front fan

Capacitor B (Compressor)

Main circuit board

Capacitor C (Front FM)

Indication lamp circuit

Front panel

Power supply cord

Rear panel

Intake air grille

HAF filter (Type B: Option)

Charcoal filter

Filter damp

Front cover

Air outlet grille

Drain cap

Exhaust duct hose

Exhaust duct hose adapter nozzle

Exhaust duct hose grille

Cover

Window panel kit “C”

Remote control

Air outlet nozzle (Option)

Screw N12

Screw N1

Screw N13

Screw N4

Screw N5

Screw N14

Screw N15

Screw N8

Screw N2

Screw N16

Instruction manual (Type A)

Instruction manual (Type B)

Carton (Type A)

Carton (Type B)

NO.

PART #

PART NAME

NO.

PART #

PART NAME

NO.

PART #

PART NAME

Optional

17

3

4

10

5

6

38

41

39

34

37

43

2

1

7

40

9

13

15

18

26

38

39

39

38

12

14

11

8

38

35

41

25

24

16

38

36

38

22

21

39

19

23

20

33

32

27

28

29

30

31

42

35

  TAD-T32G  (Service  Manual)    07.1.17  3:03  PM    ページ 17

Summary of Contents for TAD-T32G

Page 1: ...SERVICE MANUAL MODEL TAD T32G Type A B TAD T32G Service Manual 07 1 17 3 03 PM b...

Page 2: ...if the unit is to be used exclusively in one space the cooling efficiency will be enhanced by using the venting kit accessory which is included with the unit 2 OPERATIONAL FEATURES 1 COOLING OPERATION...

Page 3: ...ertical louver Emergency ON OFF switch Front panel Air outlet grille Air intake grille HAF filter inside Charcoal filter inside Filter clamp inside Air intake opening Drain water outlet LCDI Power plu...

Page 4: ...r Clock indicator Timer setting indicator Timer ON OFF indicator C F indicator Set temp indicator Mode indicator Fan speed indicator Symbols Cooling mode High speed Dehumidify mode Fan only mode Auto...

Page 5: ...power cord in any way DO NOT apply any excessive force or pressure to the power supply cord Make sure that the plug is free of dust DO NOT use an extension cord DO NOT turn on and off by inserting or...

Page 6: ...R OPERATING CYCLE MODEL OUTPUT POWER UNIT in FT2 V Hz V B T U GAL H A W CFM W uF V A W uF V W uF V W mm R22 lbs F lbs TAD T32G 20 W 16 1 2 D 36 H 508 W 418 D 915 H mm 194 258 18 24m2 115 60 104 127 12...

Page 7: ...e The setting range is from 64 F 18 C to 90 F 32 C Note When choose AUTO DEHUMIDIFY or FAN MODE temperature setting button invalid Clock Set Controls Press CLOCK button LCD clock display flashes Press...

Page 8: ...pleted after one beep Default indicator Trouble shooting when environmental tempera ture indicator failures Please check the environmental temperature indi cator on PCB if it s assembled properly and...

Page 9: ...crews from the top of the rear panel I to remove the front cover Lift up the front cover and disconnect the connecters of the circuit board and the ionizer Type A only 2 Remove six 6 screws from the b...

Page 10: ...a power failure The plug is not connected The timer is unable to work The main switch has not been pressed The set temperature is too close to the room s temperature There is something blocking the s...

Page 11: ...as dirt on a cooling unit it is important to perform a visual check first Part replacement is not necessary and accurate analysis cannot be performed with an unclean condition Check the refrigeration...

Page 12: ...sconnect the wiring of the load that is not moving from the main board apply voltage directly to the load to checkif the load is normal If the load is normal the problem is the main board Minimum set...

Page 13: ...voltage It is not rotating It is rotating Normal Measure terminal voltage of main board Check drain motor rotation Drain motor malfunction Main board malfunction Operation stops due to full water TRO...

Page 14: ...l if it is operated Check if there is loose disconnection short circuiting on connector of Full Tank Switch Also check a loose disconnection and breakage of Float Malfunction of Drain Motor Replace it...

Page 15: ...again after 5 min of disconnection from power supply Normal if the unit is operated for 30 min after disconnection from power supply Operation Circuit Board is malfunctioned if the same problem happe...

Page 16: ...room temperature drops more than 2 F 1 C from the setting temperature the compressor stops D When the room temperature is 2 F 1 C lower than the setting temperature the compressor will not start E The...

Page 17: ...F 68 F 22 C 20 C C Less than 66 F 19 C Compressor ON 9min 3min 9min 3min 6min 3min Selected fan speed Low Low Low IONIZER INDOOR MOTOR SENSOR CN 3 CN 4 CN 5 P8 P1 R S T P2 P3 P4 P7 P6 P5 COM NO CN 2...

Page 18: ...fan Capacitor A Rear FM Front fan motor Front fan Capacitor B Compressor Main circuit board Capacitor C Front FM Indication lamp circuit Front panel Power supply cord Rear panel Intake air grille HAF...

Page 19: ...TOYOTOMI CO LTD 5 17 Momozono cho Mizuho ku Nagoya 467 0855 Japan www toyotomi jp New 12 06 Printed in Japan TAD T32G Service Manual 07 1 17 3 03 PM a...