Troubleshooting
Electrical Control
c. EEPROM malfunction
f. Full-water malfunction
Full-water malfunction
Check whether the water-level switch is inserted well
Check whether the water-level switch is broken
Check PCB board or replace the main control board
Replace the water-level switch
Yes
No
Check whether the water pump is normal
Yes
Insert the water-level switch well
No
Yes
Replace the water pump
No
EEPROM malfunction
EEPROM chip is broken
Check whether the main control chip is broken
Replace the control chip
Yes
No
Check PCB board or replace the main control board
Replace EEPROM
Yes
No
Summary of Contents for CCT140A-M
Page 1: ...Service Manual MODEL CCT70A M CCT140A M...
Page 7: ...Wiring Diagrams Four way Cassette Type Wiring Diagrams C C T 7 0 A M...
Page 8: ...Wiring Diagrams Four way Cassette Type CCT140A M...
Page 13: ...Field Wiring Four way Cassette Type 10 Field Wiring Wiring chart MCC 24HRN1...
Page 14: ...Field Wiring Four way Cassette Type CCT140A M...
Page 17: ...Dimensions Outdoor Units mm Model A B C D E F H CCT140A M 900 590 378 400 330 340 1167...
Page 21: ...Wiring Diagrams Outdoor Units CCT70A M...