![Toyota 40--8FD35N Manual Download Page 43](http://html1.mh-extra.com/html/toyota/40-8fd35n/40-8fd35n_manual_1143201043.webp)
12 INSTRUMENT
en‐44
12.2.10 Maintenance indicator
MODE
The maintenance indicator will be displayed
when the maintenance hour meter exceeds
the preset service interval time, and a warn
ing sound will sound for 5 seconds each time
the key switch is turned on.
12.2.11 Menu lock indicator
MODE
(1) Switch (a)
The menu lock indicator is displayed when
the menu lock setting is active.
When the menu lock setting is active, the
Operator setting menu screen cannot be op
erated. If switch (a) is pressed for 2 seconds
or more on the status screen to open the
Operator setting menu screen, the indicator
will blink to inform that the operation is in
valid. Also, the Ecomode cannot be turned
on/off when the menu lock setting is active.
12.2.12 Load meter
(Only with Multifunction Display DX)
Returning the lift lever to neutral from lifting
position will display the weight of the load be
ing handled on the status screen. The weight
of the load is displayed in an unit of 0.01 ton.
The recommended operating condition is as
follows:
▪ Traveling and load handling operation is
stopped
▪ The mast is set in a vertical position
▪ The load height is approx. 500 mm
above the ground
NOTICE
•
If the load is less than 100kg, the meter will indicate 0.00t.
•
The load weight is displayed for about 5 seconds each time the lift lever is returned to
neutral position. The load weight is not displayed when the traveling speed is detected. To
change the display time, ask the Toyota dealer.
•
This function should be used as reference when conducting load handling operations, and
not used in business dealings or as proof of actual weight.
•
The load meter measures the load by reading the lift cylinder pressure, so this function
should not be used to check for overload when the load weight is near maximum capacity.
•
When the load is lifted to a maximum lift height, a higher weight value will be displayed
due to a residual pressure generated by the relief stop.
•
If zero point of the load meter is slightly deviated toward the minus side, the display will in
dicate 0.00t. Ask the administrator for zero point adjustment.
Load meter error display
(Only with Multifunction Display DX)
The accuracy of the load meter drops while
the load is lifted to a high position because of
the influence of the mast deflection and fric
tion. In that case, an arrow will appear at left
of the screen and the measured weight indic
ation will blink to notify the operator that the
reading is inaccurate.
To measure the load, always set the load to
a height of approx. 500mm above the ground
and set the mast vertically.
Load meter sensor error display
(Only with Multifunction Display DX)
If an error has been detected in the load
meter sensor, the display will blink to notify
the operator of an error.
Summary of Contents for 40--8FD35N