Note: If the yellow lamp or green lamp flashes when
the operation switch is OFF position, the green
lamp will flash and the motor will start rotating
to perform lifting for about 5 to 12 minutes
when turming the operation switch to ON.
(Fig. 5)
4. Turn the outlet valve lever to OPEN to supply
fuel to heater.
5. Replace the cover and attatch it with the cover
screws securely.
8
MAINTENANCE
CAUTION: Be sure to turn the operation switch to OFF and disconnect the power
supply cord from the electrical outlet before performing any checks or cleaning.
Note: Accumulated dust and water may cause problems. Check and clean the lifter before
using it.
1. Cleaning
Remove the cover and remove any dust from around the motor.
2. Clean fuel strainer
If the fuel strainer is clogged, clean it in the
following procedure.
(a) To catch the fuel which will drain out,
set a rag or folded paper towel below the
strainer cover. (Fig. 6)
(b) Loosen the two (2) screws from the strainer
cover and remove. (Fig. 6)
(c) Remove the fuel strainer and rinse with
clean fuel. (Fig. 7)
(d) Return the fuel strainer to its original position.
Replace the strainer cover and replace
screws.
(e) Wipe away any spilled fuel.
( f ) Be sure to confirm that there is no fuel
leakage from the strainer cover.
3. Draining from fuel sump
Water can collect in the fuel sump. Drain any
water from the fuel sump prior to each season's
start up.
(a) Remove the two (2) drain screws at the
bottom of the unit. (Fig. 8)
Fuel strainer
Rag
Strainer cover
Fuel strainer
Clean kerosene
Drain screw
Drain screw
Fig. 6
Fig. 7
Fig. 8
Fig. 5
Red lamp
Green lamp
Yellow lamp
Outlet valve
lever
Control box
OPERATION
switch
CLOSE
OPEN
ON
OFF