Note: When first started, the intake line contains air and a muted "THUMPING"
sound will be heard. Once the line is filled with fuel the sound will cease.
Note: If this does not stop until just before the motor stops, air is leaking into the
pipe. Check the pipe and all connections, especially the flares.
Note: If the lifter is installed correctly, a proper amount of fuel will be
pumped up in about 5 to 12 minutes at which time the motor will stop.
5. Turn the outlet valve lever to OPEN.
CAUTION: Be careful not to touch the motor fan when rotating the outlet valve
lever.
6. Remove the funnel from the fuel opening, and then store it in place.
7. Plug the hole of the fuel opening securely with the rubber cap.
8. Replace the cover and attach with cover screw. At this point, the lifter is ready
to perform automatic operation to supply fuel to the heater.
■
When Restarting The Lifter In The Next Season:
1. Remove the cover screw and remove the cover.
2. Turn the outlet valve lever to CLOSE, turn the operation switch to OFF, and put the
power supply cord into the electrical outlet.
3. Turn the operation switch to ON.
Note: If the red lamp comes on or flashes when the operation switch is OFF position, the
motor does not rotate when turning the operation switch to ON.
(a) If the outlet pipe is longer than 33 ft. (10 m),
turn the outlet valve lever to OPEN and CLOSE
repeatedly several times. When the motor starts,
set the outlet valve lever to CLOSE, and when
the motor stops, set it to OPEN. (Fig. 4)
(b) Before turning the outlet valve lever to OPEN,
quickly repeat the procedure of holding up
the lever fully and turning it to CLOSE four or
five times. To prevent air lock which may
occur in the pipe.
(c) Be sure that fuel is not leaking from any
part of the lifter as well as from the inlet/outlet
pipes and all joints.
7
Outlet valve lever
Before setting the outlet valve
lever to OPEN,quickly
repeat the procedure of
holding up the lever
fully and setting it to
CLOSE four or
five times.
Hold it up fully.
Set it to CLOSE.
OPEN
OPEN
OPEN
CLOSE
CLOSE
Fig. 4