Troubleshooting
52
TOX_Manual_Powerpackage_line-Q_en
9.2
Searching for causes of fault
Fault
Possible cause
Measure
Piston rod does not extend.
Tool jams.
Guiding columns are jammed.
Mechanically decouple the Powerpack-
age and check ease of movement by
extending and retracting.
Air pressure too low (only for assembly
direction from the bottom to the top).
Check air pressure and increase if nec-
essary.
Main control valve does not switch.
Check main control valve.
Contact authorized service personnel.
Unlockable check valves (optional
equipment) do not open.
Check non-return valves.
Contact authorized service personnel.
Faulty pneumatic hose.
Check the compressed air supply.
Contact authorized service personnel.
No execution of power stroke.
Press force not reached.
Insufficient air pressure.
Increase air pressure.
Compressed air setting on pressure
regulator in the power stroke line (op-
tional) is too low.
Increase air pressure in power stroke
line.
Pneumatic spring pressure setting is
too high or the pneumatic spring is
faulty.
Check compressed air supply of the
pneumatic spring.
Contact authorized service personnel.
Oil level is too low.
.
Air is trapped in the hydraulic oil sys-
tem.
Refilling oil and venting drive, Page
61
Power stroke valve is faulty.
Contact authorized service personnel.
Control throttle 'X' incorrectly set, over-
loaded.
Setting control throttle 'X', Page 47
No air pressure in home position.
Impinge the return stroke with air pres-
sure before initiating the fast approach
stroke.
Power stroke not triggered with
very short fast approach stroke
(only for type Q-S, X-S, S, EL
with hydraulic end position
cushioning ZHD)
The fast approach distance traveled is
too short. Required: min. 8 mm.
Set sufficient travel for fast approach
stroke before the power stroke is
switched on.
Summary of Contents for Powerpackage Q Series
Page 2: ...2 TOX_Manual_Powerpackage_line Q_en ...
Page 24: ...Technical data 24 TOX_Manual_Powerpackage_line Q_en ...
Page 54: ...Troubleshooting 54 TOX_Manual_Powerpackage_line Q_en ...
Page 56: ...Maintenance table of Powerpackage 56 TOX_Manual_Powerpackage_line Q_en ...
Page 66: ...Maintenance 66 TOX_Manual_Powerpackage_line Q_en ...
Page 68: ...Repairs 68 TOX_Manual_Powerpackage_line Q_en ...
Page 72: ...Disassembly and Disposal 72 TOX_Manual_Powerpackage_line Q_en ...
Page 74: ...Appendices 74 TOX_Manual_Powerpackage_line Q_en ...
Page 75: ......
Page 76: ......