Commissioning
46
TOX_Manual_Powerpackage_line-Q_en
7.3.1
Setting speed ratio of return stroke to fast approach stroke
The speed of the working piston in the fast approach stroke and return
stroke can be set with external exhaust air dampers on the forward stroke
and return stroke. The exhaust air dampers may have to be retrofitted.
Type
line-Q
Necessary speed ratio
Return stroke equally fast as fast approach stroke
or
Return stroke faster than the fast approach stroke
Tab. 2
Necessary speed ratio
A visual check of the speeds is generally sufficient.
1.
Set speed ratio according to the specifications.
2.
Perform test and check the speed visually.
7.3.2
Set the speed ratio between power stroke and power stroke
venting (optional)
At throttled power stroke speed
Necessary speed ratio between power stroke and power stroke venting
Power stroke speed equal to the return stroke speed of the intensifier piston
or
Power stroke speed faster than the return stroke speed of the intensifier piston
Tab. 3
Necessary speed ratio
A visual check of the speeds is generally sufficient.
1.
Set speed ratio according to the specifications.
2.
Perform test and check the speed visually.
Summary of Contents for Powerpackage Q Series
Page 2: ...2 TOX_Manual_Powerpackage_line Q_en ...
Page 24: ...Technical data 24 TOX_Manual_Powerpackage_line Q_en ...
Page 54: ...Troubleshooting 54 TOX_Manual_Powerpackage_line Q_en ...
Page 56: ...Maintenance table of Powerpackage 56 TOX_Manual_Powerpackage_line Q_en ...
Page 66: ...Maintenance 66 TOX_Manual_Powerpackage_line Q_en ...
Page 68: ...Repairs 68 TOX_Manual_Powerpackage_line Q_en ...
Page 72: ...Disassembly and Disposal 72 TOX_Manual_Powerpackage_line Q_en ...
Page 74: ...Appendices 74 TOX_Manual_Powerpackage_line Q_en ...
Page 75: ......
Page 76: ......