Installation
30
TOX_Manual_Powerpackage_line-Q_en
ü
Make sure that the system is depressurized and disconnected from the
power supply.
ü
Observe the tightening torques.
See
Chap. 4.3 Tightening torques, Page 21
.
1.
Install assembly holder of pressure switch on the drive. Make sure that
display and operating elements are easily accessible.
2.
Fasten the pressure switch in the assembly holder.
3.
Install high pressure hose on the pressure switch and on the high pres-
sure measuring connection.
4.
Connect cable of the pressure switch on the control system according
to circuit diagram.
See pressure switch ZDO operating manual.