Installation
40
TOX_Manual_FinePress_ZFS-ZFL-ZFW_en
6.3.7
Installing travel sensor (option)
7
6
2
3
5
4
1
1
Cheese head screw
2
Mounting clip
3
Straight connector
4
Flat head screw
5
Product tag
6
Fixing device
7
Counter nuts
1.
Unscrew the product tag.
2.
Screw on the fixing device together with the tag. The travel sensor is
pointing towards the press frame.
3.
Screw the rear fixing device onto the press head.
4.
Connect the cable to the evaluation unit.
5.
Screw the straight connector to the fixing device using the fastening
clip.
6.
Setting the travel sensor, Page 54
.