8.6
Setting working depth
2
1
1
Knurled screw
2
Counter nut
One rotation of the knurled screw corresponds to an adjustment of 1 mm.
Turn clockwise - decrease working depth.
Turn anticlockwise - increase working depth.
1.
The working depth can be set using the knurled screw.
2.
Secure the setting by tightening the counter nut.
8.7
Resetting the stroke counter (optional)
The stroke counter has a reset button.
è
Press the stroke counter button.