111011-16 TCVT.FMPV3
The Flush Mount Power Vent assembly has an electrical connector block mounted internally.
The external wiring from the main voltage/control module should be connected to this block.
Follow the steps below to access this block.
1. Remove the 2 top and 2 bottom screws securing the end
cap only. Remove the cover by lifting it up and off the studs. (Fig
#23 & #24).
2. Remove the 6 screws securing the blower grill to the
assembly and remove grill. (Fig #25)
3. Run the power supply wire from the fi replace to the
connector block inside the power vent assembly. (Fig #26 &
#27).
Connect wires as shwon. Connect ground to ground screw and
tightne strain relief.
4. Reposition blower grill and secure in place with previously
removed screws. Place the end cover back onto the upper tabs
and secure in place with 2 screws on top and 2 on bottom.
DECORATIVE
COVER
SCREWS
CONNECTOR
BLOCK
MAIN POWER
CONNECTIONS
GROUND
SCREW
GROUND
SCREW
SCREWS
SCREWS
Fig. #23
Fig. #25
Fig. #24
Fig. #26
Fig. #27
10
Fan Wiring
Summary of Contents for TCVT.FMPV3