111011-16 TCVT.FMPV3
The gas control system is located on the right hand side of the
fi rebox behind an access panel and the decorative panel.
1. Burner assembly, burner media and/or decorative panels
may need to be removed if already installed (see main
installation manual for details).
2. Remove access panel located on the right hand side of the
fi rebox (Fig. #12).
3. Locate and disconnect the spade connectors in the black
wire loop on the right side of the module and in the orange
wire running from the module to the socket labelled “pilot”
on the valve (Fig. # 13 and 14).
4. Using the jumper wires provided, connect the 120V “hot”
supply wire to one of the black wires from the control module.
Then connect the “hot” wire from the power vent blower to
the other black wire on the control module, (Fig. #15). The
module acts as a switch to turn on the power vent blower.
(Also see wiring diagram on Pg.13)
Fig. #13
Fig. #14
Fig. #15
ACCESS PANEL
SPADE CONNECTORS IN BLACK
WIRE LOOP
ORANGE WIRE FROM
MODULE TO VALVE
Fig. #12
SUPPLIED WIRES TO CONNECT TO
BLACK WIRE ON MODULE
HOT WIRE
FROM BLOWER
HOT WIRE FROM
120V SUPPLY
7
Control System Connection
Summary of Contents for TCVT.FMPV3
Page 15: ...111011 16 TCVT FMPV3 15 ...