Fig. #35
NOTE: The vent must not exceed a total length of 68 feet.
Any combination of rise and run may be used but must be
constrained to the boundaries of this chart. A total of 3
90° elbows or combination of other elbows equalling 90°
can be used without reducing horizontal run. For each
additional 90° elbow, or an equal combination of elbows,
reduce horizontal vent run by 2 feet. Ensure vent pipe is
properly supported.
** All dimensions are approximate.
Both rise and run may vary with different combinations of pipe.
12" Pipe
length
minimum
A
Minimum rise
B
Pipe length
C
Maximum run
D
Pipe length Max.
61"
1-12"
32 1/2"
1-24"
67"
1-18"
75 3/4"
1-48" 1-12"
73"
1-24"
9' 3 3/4"
2-48"
77 1/4"
1-12" 1-18"
13' 2"
3-48"
83 1/4"
1-24" 1-12"
17' 1/4"
4-48"
89 1/4"
1-24" 1-18"
18' 10 1/2"
1-48" 1-24"
97"
1-48"
20' 10 1/2"
5-48"
For other rise/run combinations see chart below
**
19
TC36_CSTE 071010-44
Wall Termination Venting Chart