Minimum Clearances:
Side standoffs ....................................................... 0 in.
(0 mm)
Back standoffs ...................................................... 0 in.
(0 mm)
Top standoffs ........................................................ 0 in.
(0 mm)
Bottom of appliance .............................................. 0 in.
(0 mm)
Adjacent side wall ................................................. 2 in.
(51 mm)
Ceiling to appliance ............................................ 24 in.
(610 mm)
*Mantel to appliance .................. ..........See Figure #2
**Maximum Mantel extension .. ..........See Figure #2
Mantel support ...................................................... 2 in.
(51 mm)
Vertical vent pipe ..........................................1 3/4" in.
(45 mm)
Horizontal Vent pipe (Top, sides and bottom) 1 3/4" in.
(45 mm)
Fig. #3
MANTEL
ADJACENT WALL
OR MANTEL SUPPORT
CEILING
UNIT MAY BE RECESSED UP TO 6” WITH
NON-CUMBUSTIBLE MASONRY TYPE MATERIAL
*
* MANTEL CLEARANCE
A
9”
B
6”
C
3”
** MANTEL DEPTH
D
12”
E
6 3/4”
F
1 1/2”
MANTEL CLEARANCE
CHART
Fig. #1
Fig. #2
MAY USE COMBUSTIBLE
FACING MATERIAL IN THIS AREA
NON-COMBUSTIBLE
FINISH MATERIAL
SEE FIG #7
NON-COMBUSTIBLE ZONE.
DO NOT INSTALL ANY COMBUSTIBLE MATERI-
AL, ELECTRICAL WIRING OR GAS PLUMBING IN
THIS AREA.
COMBUSTIBLE FRAMING AND
FINISH WALL ABOVE STANDOFFS
STANDOFFS
STEEL FRAMING
FIREPLACE FRONT
TOP OF LINTEL BAR
CENTER OF FLUE OUTLET
TOP STANDOFFS
5
TC36_CSTE 071010-44
Fireplace Dimensions
Minimum Clearances to Combustible Material