background image

5056.42905D

6

    TC30_ng05D 270315-16

Gas plumbing and vent connections 
should be completed before proceeding.

The logs are fragile, and should be handled 
with care. Unpack and inspect log set. There 
should be a total of seven logs. 

Position the logs as indicated by the following 
pictures. The seven main logs have holes and / 
or pins. Engage each pin in the  corresponding 
holes. The remaining two logs do not have 
holes or pins. They rest in position. Locate 
as per the diagrams (fig. # 7-15)

Note: Improper placement of logs 
will cause sooting on internal parts 
and glass. The logs may need to be 
repositioned slightly to avoid excessive 
flame impingement.

Log Placement

Fig. # 7

Fig. # 8

BASE LOG, #1

LEFT CENTER LOG, #2

Summary of Contents for TC30.NG05D

Page 1: ... to the Installation and OperatingInstructionssuppliedwiththefireplaceandshouldbekept together RefertotheInstallationandOperatingInstructionsforproper gas supply safety requirements and operating instructions 270315 16 TC30_NG05D 5056 42905D TC30 HEARTWOOD BURNER INSTALLATION INSTRUCTIONS PART TC30 NG05D FOR TC30 Series D Fireplaces ...

Page 2: ...E If this fireplace is to be used on Propane please convert prior to installtion See pages 10 12 Burner Installation 1 Place the keyhole slots in the burner overthetwoscrewslocatedinthefirebox base Fig 1 1a 2 Slide the burner back to engage the screws in the small part of the keyhole slot and tighten screws Fig 1b 3 Remove access cover from side of firebox Fig 1c Fig 1a Fig 1b SCREWS Fig 1 Fig 1c ...

Page 3: ...LATE 2 SCREWS Fig 2 Burner Grate Installation Fig 3 INTERFACE MODULE IGNITION WIRE RED FLAME SENSOR WIRE WHITE 4 Secure the electrical bulkhead plate Fig 2 and gasket to the firebox 2 screws Attach the ignition and sensor wires to the module Fig 3 ...

Page 4: ...ing and tighten Fig 3b Ensure the connections are gas tight Conceal the spark and sensor wires below the supply tubes A panel set must now be installed See InstallationandOperating Instructions manual for details 6 Position the slots of the grate securing brackets over the holes in the floor shield and secure with the two screws Fig 4 Fig 3b ...

Page 5: ...must only be used around the burner pan to cover up the gas lines and brackets 1 Pull apart the material into ember size pieces approximately 1 square and gently place them into the burner pan Do not compress leave them loose for best performance 2 Fill the burner pan with embers until level with the top of the pan at rear and gradually slope forward to the firebox floor at the front covering both...

Page 6: ...ogs as indicated by the following pictures Thesevenmainlogshaveholesand orpins Engageeachpininthe corresponding holes The remaining two logs do not have holes or pins They rest in position Locate as per the diagrams fig 7 15 Note Improper placement of logs will cause sooting on internal parts and glass The logs may need to be repositioned slightly to avoid excessive flame impingement Log Placement...

Page 7: ...5056 42905D TC30_ng05D 270315 16 7 Fig 9 Fig 10 LEFT FRONT LOG 3 LOG WITH HOLE 4 ...

Page 8: ...5056 42905D 8 TC30_ng05D 270315 16 Fig 11 Fig 12 RIGHT CENTER LOG 5 FRONT RIGHT LOG 6 ...

Page 9: ...5056 42905D TC30_ng05D 270315 16 9 Fig 14 Fig 15 Fig 13 CENTER TWIG 8 RIGHT BASE LOG 7 CENTER BASE CHUNK 9 ...

Page 10: ...xplosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete un til the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit 1 Ensure the burner pilot and gas ...

Page 11: ...ition For complete valve installation instructions refer to the instruction book included in the SIT conversion kit NG Position Fig 20 LP Position Fig 21 ADD NAME ADD DATE 5056 42905D TC30_ng05D 270315 16 11 M ra HOLE 9 Fill in the date and the name of the personwhoperformedtheconversionin the white area on the conversion label Peelofftheprotectivebackingandapply the conversion label directly over...

Page 12: ...e the plug Thread sealant will be required to ensure a gas tight connection Correct gas pressure requirement Supply Pressure Natural Gas Propane For purpose of input adjustment Minimum 5 0 WC 12 5 WC Maximum 13 9 WC 13 9 WC Manifold Pressure Maximum 3 5 WC 10 0 WC Minimum 1 6 WC 6 4 WC Note To test the gas pressure turn off the gas supply before removing the plug from the supply pressure test port...

Page 13: ...to enhance the Ember Material glow and lessen the flame height Caution Burner area may be hot Turn off the fireplace and allow the unit to cool before proceeding Caution Proper air shutter setting is a must The flame should be just orange and lazy It should NEVER be set to create sooting on internal parts and glass Flame Adjustment To Adjust 1 Open and remove window frame and set aside See Window ...

Page 14: ...D 1d PILOT SHIELD 1e TC36 NG01 BURNER WELD 1f MANIFOLD 1g 1 2 PIPE TO 1 2 TUBE CONNECTION 1h PILOT BRACKET KIT CONTENTS 2 9 PCS HEARTWOODLOG SET EMBER MATERIAL Not shown 1 BASE LOG 2 LEFT CENTER LOG 3 LEFT FRONT LOG 4 LOG WITH HOLE 5 RIGHT CENTER LOG 6 FRONT RIGHT LOG 7 RIGHT BASE LOG 8 CENTER TWIG 9 CENTER BASE CHUNK 3 ORIFICE NATURAL GAS 32 4 PILOT ASSEMBLY CONVERTIBLE INCLUDING TUBE 5 MAIN SUPP...

Page 15: ...5056 42905D TC30_ng05D 270315 16 15 ...

Page 16: ...oduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws For technical support please contact your retailer www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8 Printed in Canada ...

Reviews: