tousek
/ EN_ST-80A_04 / 25. 03. 2020
- 7 -
9/1
9/2
9/3
9/4
induction loop
outside
induction loop
inside
Induction loop input
(outside: term. 9/1+9/2, inside: term.9/3+9/4)
Connections
•
For the connection of induction loops to give an impulse
to the green request.
• With the 2-channel I-loop detector ISD 6 both loops
(inside/outside) can be evaluated.
Induction loops
•
For the use of induction loops (for Green/Opening command) the I-loop slot (ISD) of the traffic
light board STA 11 has to be equipped with an optional avalaible I-loop detector ISD 6 (2-channels).
(see page 23)
38
30
32
30
impulse switch
outside
impulse switch
inside
Impulse switch
(outside: term. 38/30, inside: term. 32/30)
Connections
•
For the connection of impulse switches on the inside
and outside to give an impulse for the green request.
The impulse is also possible via an optional, plug-in
radio receiver - see next page.
• The green switching for one or both sides is dependent
on the adjustment of the traffic light logic of the operator
control board
(see operator control board).
97
6
99
6
96
6
98
6
GREEN
outside
RED
outside
GREEN
inside
RED
inside
Traffic light outputs
(
outside:
GREEN: term. 97/6, RED: term. 99/6 -
inside:
GREEN: term. 96/6, RED: term. 98/6)
Connections
•
on the described terminals Red/Green traffic lights
(230V
max. 60W)
can be connected for inside and outside
location.
Adjustments
•
The functions of the traffic light control is determined by the settings of the connected operator control board.
These relate to the duration of the green phase and the clearance time, the traffic light at the closed door position
(whether or continuous red) and the traffic light system (both sides / one side green).
Important
•
Max. cable length between automation and traffic
light control is 25m.
•
Cable type e.g.: PVC control cable 2 x 1mm2 YSLY
or equivalent.
Connection traffic light board with operator control board
(term. 88/89)
Connections
•
Via the bus system
(see pic.)
the traffic light control board
is connected with the operator control board.
B
operator
control unit
88
89
88
89
Bus system
High
Bus system
Low
230V
max.
60W
2.2 Connections and adjustments
Traffic light control board STA 11
STA
1
1
STA
1
1
STA
1
1
STA 11
ST 80(V)A