background image

 

 

 

 

 

 

Installation Instructions

 

ELEKTROMAT SE 7.32 WS-25,40 
RP07/32WRD

 

Model: 10002245 10006

 

 

 
 
 
 
 
 
 
 
 

 

 

-en- 

 

Status: 05.07.2016

 

 

 

Summary of Contents for ELEKTROMAT SE 7.32 WS-25,40

Page 1: ...Installation Instructions ELEKTROMAT SE 7 32 WS 25 40 RP07 32WRD Model 10002245 10006 en Status 05 07 2016...

Page 2: ...2 GfA ELEKTROMATEN UK Ltd Titan Business Centre Spartan Close Warwick CV34 6RR United Kingdom sales gfa elektromaten co uk www gfa elektromaten co uk...

Page 3: ...2 8 Emergency manual operation SK rapid hand chain operator 13 9 Completing commissioning inspection 14 10 Declaration of incorporation conformance 15 Symbols Warning Potential injury or danger to lif...

Page 4: ...l be rendered null and void Safety information Installation and initial operation tasks are to be performed by trained skilled fitters only Only trained electrical craftsmen are permitted to work on e...

Page 5: ...eight 4000 N Supply voltage 1N 230 V Operating current 3 90 A Operating frequency 50 Hz Power factor cos 0 99 Maximum movement per hour 12 h 1 Class of protection IP 65 Limit switch range maximum revo...

Page 6: ...maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter...

Page 7: ...7 Mounting Eight threads are provided for mounting Use at least 2 of these Keys are used to connect to the door shaft Use a key that is at least as long as the hollow shaft 8 x M8x16 BAGAD01001_Z002...

Page 8: ...manufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carrying capacity Thor...

Page 9: ...BAGAE01003_Z003 Tighten all connection elements M8 to 25 Nm Install all other connection elements according to the specifications of the door manufacturer BAGAE01006_Z002 25 Nm Secure the keys versio...

Page 10: ...are de energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor plug Inse...

Page 11: ...11 5 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel...

Page 12: ...n C1 Capacitor M1 Motor X13 Motor plug 7 Limit switch connection F10 Thermal contact S10 Manual operation X12 DES connection 1 Safety circuit 2 Channel B RS485 3 Ground 4 Channel A RS485 5 Safety circ...

Page 13: ...ltage Electrical operation is no longer possible Warning Injury through improper operation Disconnect the voltage Adopt a secure position For drives that have a brake emergency manual operation should...

Page 14: ...on cables and cabling for damage or crushing Check that the screw connections and plug connections are fitted properly with a good electric contact Emergency manual operation Check the function with t...

Page 15: ...ronments Electromagnetic compatibility EMC Part 6 3 Generic standard Emission standard for residential commercial and light industrial environments We undertake to transmit in response to a reasoned r...

Page 16: ...16...

Reviews: