3.1 Terminal assignment
Barrier control board ST 80(V)A
L N
boom
lamp
24Vd.c.
magnetic
clamp
24Vd.c.
I-loop
1
I-loop
2
signal contact “attendance”
ISD-channel-1/-2
grounding
230V
a.c.
Phase
50Hz
zero
line
Signal
lamp
230V
max.
100W
41
42
43
44
45
46
50
52
31
37
32
30
33
30
34
30
54
20
21
22
23
80
81
0
1
2
10
11
L N
PHC-transmitter
PHC-receiver
8.k2
PHC-contact
contact edge
main
closing
edge
70
71
74
75
9/1
9/2
9/3
9/4
78
79
– + – +
PHC-supply
ST
OP-button
barrier
door
contact
connection
possibility
for
motor
condenser
(if not connected yet to the motor !)
Warning
•
Before taking off the control cover, the
mains switch must be turned off!
•
If the control is power supplied, its inner part is under tension.
•
In order to avoid electrical strokes, the safety regulations have to be
respected.
•
The device may only be connected by trained professionals.
•
The product is not suitable for installation in explosion-hazardous
areas.
•
An all-pole disconnecting mains switch with a contact opening gap of
min. 3 mm has to be foreseen. The barrier facility has to be secured
according to the valid safety regulations!
•
IMPORTANT: The control lines (buttons, radio, photocells, etc.) have
to be laid separately from the 230V lines (supply line, motors, signal
lamp).
The stop input has no emergency stop function! - In order to ensure the emergency stop function, provide
the supply line with an all-pole disconnecting emergency stop switch, that locks after actuation!
black
(opening)
gray
(blue)
brown
(closing)
grounding
motor
connection