![TOUGHCUT Diamond 400 Instruction Manual Download Page 22](http://html1.mh-extra.com/html/toughcut/diamond-400/diamond-400_instruction-manual_1140414022.webp)
5.5.4 BUTTON / DESCRIPTION
5.5.5 EXPLICIT DECLARATION
5.5.6 PARAMETER DESCRIPTION
Long press 4 seconds:Modify the current value.
Functional status short press:Remove or withdraw from the interface.
Long press 4 seconds:Sensor adaptive calibration.
Functional status short press:Modify the current display parameters.
Long press 4 seconds:Change the direction of incremental sensor .
Functional status short press:changing-over Or shift parameters.
Long press 4 seconds:Enter the menu .
Short press:Modify the confirm button.
Combination key:From the initial value.
Short press:opposite/absolute mode switch
kindly reminder:Ask the client to pay attention to the small icons on the buttons and understand the meaning of the
icons,Will be more rapid and simple operation of digital display meter.
number Function description parameter
Default
parameters Parameter description
remarks
P01
Measurement mode
switching
Length / inch / angle 0
0:Length pattern
1:inch
2:Angle pattern
After modification,Press the
confirmation key:
P02
Set the current
position ( Or through
the shortcut keys)
-999999~~99999999 0
Need to enter the password:
1234
After modification,Press the
confirmation key:
P03
Measurement
direction Or (through
a shortcut key)
0
1
0
0 or 1 represents two
directions
Change the direction of the sensor
and change the direction of the
measurement
P04
Length resolution
0.01 0.1 1
0.01
Length mode default single:
mm
After modification,Press the
confirmation key:
P05
Timing off screen
0:lock
1:open
0
0:Lock the automatic closing
screen
1:5 minutes after the default
screen off screen
Wake up by any key
P06
Ratio coefficient
0.00001~2.99999
1
Display value = Real value
measurement × Ratio
coefficient
After modification,Press the
confirmation key:
P07
Adaptive calibration GO - - --
GO
GO:get into the state, Slow
motion(Can move over and
over)sensor,About 10 seconds
to move 150MM,Return to the
current value after learning to
complete
If the correction is not successful,
adjust the distance between the
sensor and the magnetic stripe,The
distance between the reading head
and the magnetic ruler is controlled
in 1mm-2mm
-22-
Summary of Contents for Diamond 400