![TOUGHCUT Diamond 400 Instruction Manual Download Page 19](http://html1.mh-extra.com/html/toughcut/diamond-400/diamond-400_instruction-manual_1140414019.webp)
-19-
Fig.5.4
5.4 M30 ANGLE METER INSTRUCTION MANUAL
- 5 digital tube display, clear and easy to read
- Measuring scope:±180°
- Automatically read the angle for unexpected power outage
- Buttons can be locked, avoiding faulty operation.
- Angle data react quickly
- Initial angle setting(0° )
- Final angle setting(45°)
5.4.1 SPECIFICATIONS/PERFORMANCE
5.4.2 BUTTON INSTRUCTION
5.4.3 DISPLAY INSTRUCTION
Electric performance
Mechanical performance
Resolution ratio
0.1°,0.5°
Out dimension
74*36*32mm
Measurement range
±180°
Cutout size
66*32mm
Current
Max.50mA
Fixed mode
Fixed by screw on back
Power
DC:9V~24V;AC:9V~24V
Sensor
Default wire length 2.5m
Operating temperature 0
℃
~+50
℃
Waterproofing grade
Data display instrument IP40
,
sensor IP65
Storage temperature
-10
℃
~+60
℃
Weight
Max.230g
short press
:
ESC long press
:
clear the result, long press again will turn back to earlier result
short press
:
Increase long press
:
show initial angle, initial angle can be set in menu P06, operate cautiously
short press
:
Move to next long press
:
Invalid
short press
:
Confirm long press
:
entering into menu
Display content
Info. Statement
-179.9~180.0
Display the measured angle
E30
Display item no. when turning on
Err06
Sensor fault
:
1
)
sensor damaged
:
2
)
sensor wire damaged
:
3
)
display function damage
Err
Beyond Angle linear correction, calibration failure
Summary of Contents for Diamond 400
Page 54: ......