INSTALLATION PROCEDURE
Install the Spout
To Install Deck-Mounted models
Secure the spout to the countertop with the included mounting hardware.
Make sure that the spout is mounted with the head directed towards the center of the lavatory.
To Install Wall-Mounted models
1. Place mounting template on wall at
desired location and mark holes.
2. Drill a 5/8” (16 mm) diameter hole at
the spout mounting location (center).
3. Drill four pilot holes at marked locations.
For fastening to wood, drill holes Φ7/64” (2.7 mm).
For fastening to drywall or tile, drill holes
Φ3/16” (5 mm) and insert anchors until
flush. Tap lightly with a hammer if needed.
To Install Libella and Axiom Wall-Mounted models
4. Place mounting bracket against wall and
fasten securely with the provided screws.
5. Pass the hose and sensor cord through
the mounting bracket respectively.
6. Tighten the set screw with the provided
2.5 mm hex wrench from the bottom to
secure the spout to the mounting bracket.
To Install Helix Wall-Mounted models
4. Feed the hose tube and sensor cord through
the 5/8” (16 mm) hole in center. Place spout
against wall and fasten securely with
the provided screws.
5. Pass the escutcheon over the spout.
6. Fasten the escutcheon to the bracket until hand-tight.
NOTE
Reinforce the wall area behind the spout
installation location. The addition of
2×4 stringer is highly recommended.
ENGLISH